<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Medidores de energía &#8211; Softbi</title>
	<atom:link href="https://tienda.softbi.com.mx/categoria-producto/medidores/feed/" rel="self" type="application/rss+xml" />
	<link>https://tienda.softbi.com.mx</link>
	<description>Venta de equipo medición</description>
	<lastBuildDate>Thu, 04 Mar 2021 00:05:25 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://tienda.softbi.com.mx/wp-content/uploads/2021/01/cropped-xicon-softbi-32x32.png</url>
	<title>Medidores de energía &#8211; Softbi</title>
	<link>https://tienda.softbi.com.mx</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190173959</site>	<item>
		<title>Single Phase energy Meter ADL10E</title>
		<link>https://tienda.softbi.com.mx/producto/single-phase-energy-meter-adl10e/</link>
					<comments>https://tienda.softbi.com.mx/producto/single-phase-energy-meter-adl10e/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Thu, 04 Mar 2021 00:02:02 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1072</guid>

					<description><![CDATA[&#160; 1. General ADL10 has a compact design DIN Rail mounting kWh meter, and it is very easy to install. It is suitable to the electrical energy statistic and management of internal of factories, buildings, schools, hospitals etc.. &#160; 2. Technical Feature]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><strong><em><span data-spm-anchor-id="a2700.wholesale.0.i35.e262b252zCdaA9">1. General</span></em></strong></p>
<p>ADL10 has a compact design DIN Rail mounting kWh meter, and it is very easy to install. It is suitable to the electrical energy statistic and management of internal of factories, buildings, schools, hospitals etc..</p>
<p>&nbsp;</p>
<p><strong><em>2. Technical Feature</em></strong></p>
<p><strong><em><img fetchpriority="high" decoding="async" src="https://sc01.alicdn.com/kf/HTB13nvev29TBuNjy1zbq6xpepXau/200461481/HTB13nvev29TBuNjy1zbq6xpepXau.jpg" alt="Single Phase energy Meter ADL10E" width="500" height="368" data-src="//sc01.alicdn.com/kf/HTB13nvev29TBuNjy1zbq6xpepXau/200461481/HTB13nvev29TBuNjy1zbq6xpepXau.jpg" data-alt="Single Phase energy Meter ADL10E" data-width="500" data-height="368" /></em></strong></p>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/single-phase-energy-meter-adl10e/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1072</post-id>	</item>
		<item>
		<title>F-MPM110 Multifunction Electric Power Meter</title>
		<link>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/</link>
					<comments>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 23:49:05 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1070</guid>

					<description><![CDATA[Features Suit for LV/ HV Voltage System For low voltage system, direct connect up to 690 V (L-L) AC For high voltage system, support connect up to 65kV Ture-RMS Measuring Parameter True-RMS measuring parameters includes: U, I, P, Q, S, PF, F, kWh, kvarh, kVAh Demand Calculation 2 kinds of demand modes: fixed block and [...]]]></description>
										<content:encoded><![CDATA[<div>
<div id="o5si8">
<div id="ali-anchor-AliMaya-3xonw" data-section="AliMaya-3xonw" data-section-title="Features" data-spm-anchor-id="a2700.details.0.i30.70cf263f6Lhp1Z">Features</div>
</div>
<div>
<div id="it25d">
<p><b>Suit for LV/ HV Voltage System</b><br />
For low voltage system, direct connect up to 690 V (L-L) AC<br />
For high voltage system, support connect up to 65kV</p>
<p><b>Ture-RMS Measuring Parameter</b><br />
True-RMS measuring parameters includes:<br />
U, I, P, Q, S, PF, F, kWh, kvarh, kVAh</p>
<p><b>Demand Calculation</b><br />
2 kinds of demand modes: fixed block and rolling block</p>
<p><b>Power Quality Analysis</b><br />
31st Harmonic analysis, K factor, unbalance etc.</p>
<p><b>TOU (Multi-tariff billing), Historical Data of 31 Days and 12 Months</b><br />
TOU, 4 tariffs, 8 time period in 24 hours</p>
<p><b>Max./ Min. Record (U, I, P, Q*, S*)</b></p>
<p><b>Under/ Over Limit Alarm</b></p>
<p><b>64M Bit Memory, Build-in Web</b><br />
Real-time data inquiry by Web<br />
Save monitoring data (Time interval<br />
settable 1min, 5 min, 10min,15min, 30min)<br />
Support FTP for download memory data</p>
<p><b>CO2 (Carbon Dioxide) Calculation for kWh</b></p>
<p><b>Multiple Communication</b><br />
BACnet MS/TP Protocol (RS485 port)<br />
MODBUS-RTU Protocol (RS485 Port)<br />
MODBUS-TCP/IP Protocol (Ethernet port )</p>
<p><b>DI / DO</b></p>
<p><b>High Accuracy</b><br />
Active energy: according to IEC62053-22, class 0.5s<br />
Reactive energy: according to IEC62053-23, class 2</p>
</div>
</div>
</div>
<div>
<div id="nqgpt">
<div id="ali-anchor-AliMaya-gugr8" data-section="AliMaya-gugr8" data-section-title="Specification">Specification</div>
</div>
<div>
<div id="1isu5">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div><b>Basic Function</b></div>
</td>
</tr>
<tr>
<td rowspan="11">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<p>Real time metering</p></div>
</td>
<td>
<div>Voltage</div>
</td>
<td colspan="2">
<div>Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg</div>
</td>
</tr>
<tr>
<td>
<div>Current</div>
</td>
<td colspan="2">
<div>Ia, Ib, Ic, In, Iavg</div>
</td>
</tr>
<tr>
<td>
<div>Power</div>
</td>
<td colspan="2">
<div>Pa, Pb, Pc, ∑P, Qa, Qb, Qc, ∑Q, Sa, Sb,Sc, ∑S</div>
</td>
</tr>
<tr>
<td>
<div>Power Factor</div>
</td>
<td colspan="2">
<div>PFa, PFb, PFc, ∑PF</div>
</td>
</tr>
<tr>
<td>
<div>Energy</div>
</td>
<td colspan="2">
<div>kWh, kvarh, kVAh *</div>
</td>
</tr>
<tr>
<td>
<div>CO2 (Carbon dioxide)</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td>
<div>Frequency</div>
</td>
<td colspan="2">
<div>F</div>
</td>
</tr>
<tr>
<td>
<div>Demand &amp; Max. Demand</div>
</td>
<td colspan="2">
<div>Dmd_I, Dmd_P, Dmd_Q ,Dmd_S</div>
</td>
</tr>
<tr>
<td>
<div>Max./ Min. Value</div>
</td>
<td colspan="2">
<div>Max./ min. (U, I, P, Q*, S*)</div>
</td>
</tr>
<tr>
<td>
<div>Multi-tariff Energy *</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td>
<div>Phase Angle *</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td rowspan="5">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Power Quality Analysis</div>
</div>
</td>
<td>
<div>Unbalance</div>
</td>
<td colspan="2">
<div>U_unbl *, I_unbl *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic (31st )</div>
</td>
<td colspan="2">
<div>THDu, THDi, TOHDu, TOHDi, TEHDu, TEHDi, HRU *, RHI *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic RMS (0-31st )</div>
</td>
<td colspan="2">
<div>Harmonic RMS-U *, Harmonic RMS-I *, Harmonic RMS-P *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic energy (1st -13th )</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td colspan="3">
<div>Voltage crest factor, current K factor, Load rate, Voltage deviation, Frequency deviation<br />
Running time record for power-on period and qualified voltage &amp; current *</div>
</td>
</tr>
<tr>
<td>
<div>Setpoint Alarm</div>
</td>
<td colspan="3">
<div>Over/ under limit alarm</div>
</td>
</tr>
<tr>
<td>
<div>3DI +2 DO</div>
</td>
<td colspan="3">
<div>3 status input + 2 relay output</div>
</td>
</tr>
<tr>
<td>
<div>RS485</div>
</td>
<td colspan="3">
<div>Modbus-RTU protocol</div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>
<div>Record Function</div>
</div>
</td>
<td colspan="3">
<div>SOE (event log), Real-time clock ( yyyy-mm-dd hh:mm:ss) *</div>
</td>
</tr>
<tr>
<td colspan="3">
<div>Voltage/ frequency deviation, Voltage unbalance record</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="6j697">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div><b>Optional Module </b></div>
</td>
</tr>
<tr>
<td>
<div>SW</div>
</td>
<td>
<div>4 status input (wet contact)</div>
</td>
<td>
<div>LAN</div>
</td>
<td>
<div>64M bit memory + Ethernet TCP/IP</div>
</td>
</tr>
<tr>
<td>
<div>SD</div>
</td>
<td>
<div>4 status input (dry contact)</div>
</td>
<td>
<div>AI</div>
</td>
<td>
<div>2 analog input (4-20mA)</div>
</td>
</tr>
<tr>
<td>
<div>C *</div>
</td>
<td>
<div>The 2nd RS485</div>
</td>
<td>
<div>AO</div>
</td>
<td>
<div>2 analog output (4-20mA)</div>
</td>
</tr>
<tr>
<td>
<div>Ep *</div>
</td>
<td>
<div>2 pulse output</div>
</td>
<td>
<div>BA</div>
</td>
<td>
<div>BACnet MS/TP protocol</div>
</td>
</tr>
<tr>
<td>
<div>R</div>
</td>
<td>
<div>2 relay output</div>
</td>
<td>
<div></div>
</td>
<td>
<div></div>
</td>
</tr>
<tr>
<td colspan="4">
<div>* means some of function can&#8217;t be read through BACnet communication port</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="qf90d">
<table class="aliDataTable">
<tbody>
<tr>
<td>
<div><b>Parameter</b></div>
</td>
<td>
<div><b>Accuracy</b></div>
</td>
<td>
<div><b>Resolution</b></div>
</td>
<td>
<div><b>Measuring Range</b></div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>
<div></div>
<p>Voltage</p></div>
</td>
<td rowspan="2">
<div>
<div></div>
<p>0.2%</p></div>
</td>
<td rowspan="2">
<div>
<div></div>
<p>0.01V</p></div>
</td>
<td>
<div>Direct: 690Vph-ph</div>
</td>
</tr>
<tr>
<td>
<div>PT primary: 0.001kV~65kV (settable)<br />
PT secondary: 1~398V (settable)</div>
</td>
</tr>
<tr>
<td>
<div>Current</div>
</td>
<td>
<div>0.2%</div>
</td>
<td>
<div>0.001A</div>
</td>
<td>
<div>CT primary: 1~9,999A (settable)<br />
CT secondary: 1 A or 5A</div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>Power</div>
</td>
<td rowspan="2">
<div>0.5%</div>
</td>
<td rowspan="2">
<div>0.1W/var/ VA</div>
</td>
<td>
<div> each phase: 0~649.9MW/ Mvar/ MVA</div>
</td>
</tr>
<tr>
<td>
<div>Total: 0~1949.8MW/ Mvar/ MVA</div>
</td>
</tr>
<tr>
<td>
<div>Power Factor</div>
</td>
<td>
<div>0.5%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>-1.000~+1.000</div>
</td>
</tr>
<tr>
<td>
<div>Frequency</div>
</td>
<td>
<div>0.01</div>
</td>
<td>
<div>0.01Hz</div>
</td>
<td>
<div>45~ 65 Hz</div>
</td>
</tr>
<tr>
<td>
<div>Active Energy</div>
</td>
<td>
<div>0.5%</div>
</td>
<td>
<div>0.1kWh</div>
</td>
<td>
<div>0~ 99,999,999.9 kWh</div>
</td>
</tr>
<tr>
<td>
<div>Reactive Energy</div>
</td>
<td>
<div>2.0%</div>
</td>
<td>
<div>0.1kvarh</div>
</td>
<td>
<div>0~ 99,999,999.9 kvarh</div>
</td>
</tr>
<tr>
<td>
<div>Apparent Energy</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.1kVAh</div>
</td>
<td>
<div>0~ 99,999,999.9 kVAh</div>
</td>
</tr>
<tr>
<td>
<div>THD</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
<tr>
<td>
<div>Individual Harmonic</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
<tr>
<td>
<div>Un-balance</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="r9shd">
<table class="aliDataTable">
<tbody>
<tr>
<td>
<div>Connection mode</div>
</td>
<td>
<div>3-phase 3-wire, 3-phase 4-wire, 1-phase 2-wire</div>
</td>
<td rowspan="5">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<p>Communicati-on</p>
</div>
</td>
<td rowspan="2">
<div>
<div></div>
<div></div>
<p>Modbus-RTU Protocol</p></div>
</td>
<td rowspan="2">
<div>RS485 serial<br />
Baud rate: 2400, 4800, 9600, 19200, 38400bps<br />
Address: 1~247</div>
</td>
</tr>
<tr>
<td>
<div>Metering</div>
</td>
<td>
<div>True RMS, 1 sec refresh time</div>
</td>
</tr>
<tr>
<td>
<div>
<p>Input</p></div>
</td>
<td>
<div>Rate current: 1A or 5A<br />
Rate voltage:<br />
Direct 120, 220V, 240V, 277V, 398Vph-N (optional)<br />
PT secondary: 1~398V (settable)<br />
Frequency: 50/ 60Hz</div>
</td>
<td>
<div>Modbus-TCP/ IP</p>
</div>
</td>
<td>
<div>Ethernet communication port<br />
Support connect 10M/100M ethernet, Modbus TCP/IP, Web, FTP</div>
</td>
</tr>
<tr>
<td>
<div>
<div></div>
<div></div>
<p>Overload</p></div>
</td>
<td>
<div>120% of rated, continuously<br />
Instantaneous current: 10 times/ sec<br />
Instantaneous voltage: 2 times/ sec</div>
</td>
<td rowspan="2">
<div>
<div>BACnet MS/TP protocol</div>
</div>
</td>
<td rowspan="2">
<div>RS485 serial</p>
<div>Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 76800bps</p>
<p>Address: 1&#8230;127, excluding 99</p></div>
</div>
</td>
</tr>
<tr>
<td>
<div>Status input</div>
</td>
<td>
<div>Wet contact, external power supply</div>
</td>
</tr>
<tr>
<td>
<div>Relay output</div>
</td>
<td>
<div>Node capacity: 250VAC/5A</div>
</td>
<td rowspan="3">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Dimension</p>
<p>(L x W x H)</p>
</div>
</div>
</td>
<td colspan="2" rowspan="3">
<div>F-MPM110:</p>
<p>Panel: 96 x 96 x 13.5 mm</p>
<p>Cut-out: 90 x 90 x 58.6 mm (basic)</p>
<p>90 x 90 x 80.1 mm (optional module)</p>
<p>F-MPM110-DR:</p>
<p>Panel: 96 x 96 x 12 mm</p>
<p>Cut-out: 90 x 90 x 58.6 mm (basic)</p>
</div>
</td>
</tr>
<tr>
<td>
<div>Pulse output</div>
</td>
<td>
<div>Pulse constant: 1000~9999 programmable<br />
Pulse width: 60~100ms programmable<br />
Formula: 1 pulse = (1÷ pulse constant ×PT ×CT) kWh</div>
</td>
</tr>
<tr>
<td>
<div>
<div></div>
<p>Power supply</p></div>
</td>
<td>
<div>85 ~265VAC,85~265VDC (When select P1)<br />
100~420VAC, 100~400VDC (When select P2)</div>
</td>
</tr>
<tr>
<td>
<div>Power loss</div>
</td>
<td>
<div>&lt;5VA</div>
</td>
<td>
<div>Weight</div>
</td>
<td colspan="2">
<div>Basic unit: approx 550gr.<br />
Optional module: 50gr.</div>
</td>
</tr>
<tr>
<td>
<div>IP index</div>
</td>
<td>
<div>IP52 (front panel) and IP30 (case)</div>
</td>
<td rowspan="4">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Environment</p>
</div>
</div>
</td>
<td rowspan="2">
<div>Main Module &amp; and other Modules</div>
</td>
<td rowspan="2">
<div>Operating temperature: -10℃~ +55 ℃<br />
Storage temperature: -40℃~ +70 ℃<br />
Humidity: 5%~95% non-condensing</div>
</td>
</tr>
<tr>
<td>
<div>Power frequency withstand voltage</div>
</td>
<td>
<div>AC 2KV/minute</div>
</td>
</tr>
<tr>
<td>
<div>Insulation resistance</div>
</td>
<td>
<div>≥50MΩ</div>
</td>
<td rowspan="2">
<div>BACnet Module</div>
</td>
<td rowspan="2">
<div>Operating temperature: 0℃~ +50 ℃</p>
<p>Storage temperature: -5℃~ +75 ℃</p>
<p>Humidity: 10%~95% non-condensing</p></div>
</td>
</tr>
<tr>
<td>
<div>Impulse withstand voltage</div>
</td>
<td>
<div>4kV (peak), 1.2/50uS</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="1v3tv">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div>
<div><b>Standard(EMC)</b></div>
</div>
</td>
</tr>
<tr>
<td>
<div>Electrostatic discharge immunity test</div>
</td>
<td>
<div>IEC 61000-4-2,Level 4</div>
</td>
<td>
<div>Surge immunity test (1, 2/50μs~8/20μs)</div>
</td>
<td>
<div>IEC 61000-4-5,Level 3</div>
</td>
</tr>
<tr>
<td>
<div>Radiated immunity test</div>
</td>
<td>
<div>IEC 61000-4-3,Level 3</div>
</td>
<td>
<div>Conducted emissions</div>
</td>
<td>
<div>EN 55022,Class B</div>
</td>
</tr>
<tr>
<td>
<div>Electrical fast transient /burst immunity test</div>
</td>
<td>
<div>IEC 61000-4-4,Level 4</div>
</td>
<td>
<div>Radiated emissions</div>
</td>
<td>
<div>EN 55022,Class B</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div>
<div id="xbmo5">
<div id="ali-anchor-AliMaya-tbi65" data-section="AliMaya-tbi65" data-section-title="Installation">Installation</div>
</div>
<div>
<div id="cy9pn">
<div><img decoding="async" src="https://sc02.alicdn.com/kf/HTB11LwNX2jsK1Rjy1Xaq6zispXaS/231921809/HTB11LwNX2jsK1Rjy1Xaq6zispXaS.jpg" width="750" height="174" data-src="//sc02.alicdn.com/kf/HTB11LwNX2jsK1Rjy1Xaq6zispXaS/231921809/HTB11LwNX2jsK1Rjy1Xaq6zispXaS.jpg" /></div>
</div>
</div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1070</post-id>	</item>
		<item>
		<title>ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase</title>
		<link>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/</link>
					<comments>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 23:43:47 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1060</guid>

					<description><![CDATA[ETCR4700 Three Phase Digital Phase Meter 0.0mA~400.0A 0.00V~600V 3 Phase Meter Product Description 1. Intelligent design, reduce the complexity of operation, reduce the possibility of misoperation, with high precision, high stability, low power consumption, easy to use and other advantages. 2. The meter adopts large caliber current clamp, suitable for thick wire and large current testing site, [...]]]></description>
										<content:encoded><![CDATA[<p><strong><span data-spm-anchor-id="a2700.details.0.i36.6bfe57d28lNi1C">ETCR4700 Three Phase Digital Phase Meter 0.0mA~400.0A 0.00V~600V 3 Phase Meter</span></strong></p>
<div id="ali-anchor-AliPostDhMb-c8p9k" data-section="AliPostDhMb-c8p9k" data-section-title="Product Description">
<div id="ali-title-AliPostDhMb-c8p9k">Product Description</div>
<div>
<p data-spm-anchor-id="a2700.details.0.i37.6bfe57d28lNi1C">
<p>1. Intelligent design, reduce the complexity of operation, reduce the possibility of misoperation, with high precision, high stability, low power consumption, easy to use and other advantages.</p>
<p>2. The meter adopts large caliber current clamp, suitable for thick wire and large current testing site, Max current range to 600A.</p>
<p>3. Adopt voltage transformer and current clamp to input, no high voltage inside the meter, complete isolation between 3 input channels, safe and reliable.</p>
<p>4. With USB interface, Data storage: 500 groups. Through the system software to upload the storage data to computer, convenient to read, save, report, print historical data, etc.</p>
<p>&nbsp;</p>
<p><strong>Technical Specification</strong></p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td height="27">Power Supply</td>
<td>   DC9V alkaline batteries(1.5V LR6×6)</td>
</tr>
<tr>
<td height="27">   Clamp</td>
<td>   35mm x 40mm</td>
</tr>
<tr>
<td height="27">   LCD</td>
<td>   240dotsX160dots</td>
</tr>
<tr>
<td rowspan="9" height="241">   Range</td>
<td>   Voltage:AC 0.00V~600V</td>
</tr>
<tr>
<td height="27">   Current:AC 0mA~600A</td>
</tr>
<tr>
<td height="27">   Phase:0.0°~360.0°</td>
</tr>
<tr>
<td height="27">   Frequency:45.00Hz~65.00Hz</td>
</tr>
<tr>
<td height="27">   Active power:0.0W~240kW</td>
</tr>
<tr>
<td height="27">   Reactive power:0.0VAR~240kVAR</td>
</tr>
<tr>
<td height="27">   Apparent Power:0.0VA~240kVA</td>
</tr>
<tr>
<td height="27">   Power factor :-1~+1</td>
</tr>
<tr>
<td height="27">   Current vector:0A~1800A</td>
</tr>
<tr>
<td rowspan="9" height="241">   Resolution</td>
<td>   Voltage:AC 0.01V</td>
</tr>
<tr>
<td height="27">   Current:AC 1mA</td>
</tr>
<tr>
<td height="27">   Phase:0.1°</td>
</tr>
<tr>
<td height="27">   Frequency:0.01Hz</td>
</tr>
<tr>
<td height="27">   Active power:0.1W</td>
</tr>
<tr>
<td height="27">   Reactive power:0.1VAR</td>
</tr>
<tr>
<td height="27">   Apparent Power:0.1VA</td>
</tr>
<tr>
<td height="27">   Power factor:0.001</td>
</tr>
<tr>
<td height="27">   Current vector: 0.1A</td>
</tr>
<tr>
<td height="27">   Accuracy</td>
<td>   ±0.5% range</td>
</tr>
<tr>
<td height="27">   Date Storage</td>
<td>   500 sets</td>
</tr>
<tr>
<td height="27">   Data upload function</td>
<td>   USB interface, the stored data upload computer, easy to analyze management data</td>
</tr>
<tr>
<td height="27">   Auto Power-off</td>
<td>   15 minutes off automatically</td>
</tr>
<tr>
<td rowspan="2" height="54">   Power Consumption</td>
<td>   With backlight: MAX working Current about 80mA, the battery can work continuously for 8 hours</td>
</tr>
<tr>
<td height="27">   without backlight:working current about 50mA,the battery can work continuously for 12 hours</td>
</tr>
<tr>
<td height="27">   Working environment</td>
<td>   -10℃~40℃;below 80%Rh</td>
</tr>
<tr>
<td height="27">   Store environment</td>
<td>   -10℃~60℃; below 70%Rh</td>
</tr>
<tr>
<td rowspan="2" height="54">   Phase sequence</td>
<td>   Positive: U1, U2, U3 or I1, I2, I3 The cursor flashes from left to right</td>
</tr>
<tr>
<td height="27">   Inverting: U1, U2, U3 or I1, I2, I3 The cursor flashes from right to left</td>
</tr>
<tr>
<td rowspan="2" height="54">   The phase range of the measured signal when measuring phase</td>
<td>   Measuring U1-U2 phase: 30V ~ 500V</td>
</tr>
<tr>
<td height="27">   Measuring U1-I2 orI1-U2 Phase:10V~500V,10mA~10.00A</td>
</tr>
<tr>
<td height="27">   Test line length</td>
<td>   1.5m</td>
</tr>
<tr>
<td height="27">   Current clamp length</td>
<td>   2 m</td>
</tr>
<tr>
<td height="27">   measure time</td>
<td>   2s/time</td>
</tr>
<tr>
<td height="27">   Data Hold</td>
<td>   Press the HOLD button during the test to hold the data, the «DH» symbol is displayed</td>
</tr>
<tr>
<td height="27">   input resistance</td>
<td>   Test voltage input impedance is:1MΩ</td>
</tr>
<tr>
<td height="27">   Low battery</td>
<td>   When battery voltage decreases to about 7.2V, battery voltage low icon will display, reminding to replace battery.</td>
</tr>
<tr>
<td height="27">   Withstanding Voltage</td>
<td>   Between the instrument line and the shell to withstand 1000V / 50Hz sine wave AC voltage for 1 minute</td>
</tr>
<tr>
<td height="27">   Insulation</td>
<td>   Between the meter line and the jacket shell ≥ 100MΩ</td>
</tr>
<tr>
<td height="27">   Structure</td>
<td>   Double insulated, with insulated vibration-proof jacket</td>
</tr>
<tr>
<td height="27">   Protection Type</td>
<td>   IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution 2</td>
</tr>
<tr>
<td height="27">   Weight</td>
<td>   1360g</td>
</tr>
<tr>
<td height="27">   Dimension</td>
<td>   196mm×92mm×54mm</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://sc01.alicdn.com/kf/H3e6c12009fa743acb2cd16e4098cf507U/200428247/H3e6c12009fa743acb2cd16e4098cf507U.jpg" alt="ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase Meter" width="750" height="750" data-src="//sc01.alicdn.com/kf/H3e6c12009fa743acb2cd16e4098cf507U/200428247/H3e6c12009fa743acb2cd16e4098cf507U.jpg" data-alt="ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase Meter" /></div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1060</post-id>	</item>
		<item>
		<title>Medidor de eficiencia energetica</title>
		<link>https://tienda.softbi.com.mx/producto/medidor-de-eficiencia-energetica/</link>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 21:54:29 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/producto/medidor-de-eficiencia-energetica/</guid>

					<description><![CDATA[Product Description 1. Test function ★ Waveform real-time display (4 channels voltage/4 channels current). ★ True RMS values of voltages and currents. ★ The DC components of voltages. ★ Peak current and voltage values. ★ Minimum and maximum half-cycle RMS current and voltage values. ★ Pharos diagram display. ★ Measurement of each harmonic up to [...]]]></description>
										<content:encoded><![CDATA[<div class="J_module" style="margin:0px;padding:0px">
<div class="magic-0" style="margin:0px;padding:0px;border:0pxsolidblack;flex-direction:column;align-content:flex-start;flex-shrink:0"><span class="magic-1" id="ali-anchor-AliMagic-5ksn5c" data-section="AliMagic-5ksn5c" data-section-title="Product Description" style="margin:0px;padding:8px0px4px;border-width:0px0px2px;border-style:solid;flex-direction:column;align-content:flex-start;flex-shrink:0;font-size:2.4rem;font-family:Roboto;font-style:normal"><br />
Product Description</span>
</div>
</div>
<div class="J_module" style="margin:0px;padding:0px">
<div style="margin:0px;padding:0px">
<div class="magic-2" style="margin:0px0px1rem;padding:0px;border:0pxsolidblack;flex-direction:column;align-content:flex-start;flex-shrink:0">
<div class="magic-3" style="margin:0px;padding:0px;border:0pxsolidblack;flex-direction:column;align-content:flex-start;flex-shrink:0;vertical-align:top">
<div class="magic-4" style="margin:0px;padding:0px0.4rem;border:0pxsolidblack;flex-direction:column;align-content:flex-start;flex-shrink:0;vertical-align:top">
<div class="magic-5" style="margin:0px;padding:0.4rem0px;border:0pxsolidblack;flex-direction:column;align-content:flex-start;flex-shrink:0;vertical-align:top">
<div class="magic-6" style="margin:0px;padding:0px;font-size:1.4rem"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">1. Test function</b></p>
<p>★ Waveform real-time display (4 channels voltage/4 channels current).<br />
★ True RMS values of voltages and currents.<br />
★ The DC components of voltages.<br />
★ Peak current and voltage values.<br />
★ Minimum and maximum half-cycle RMS current and voltage values.<br />
★ Pharos diagram display.<br />
★ Measurement of each harmonic up to order 50.<br />
★ Bar charts show harmonic ratios of current and voltage of each phase.<br />
★ Total harmonic distortion (THD).<br />
★ Active, reactive, apparent power, by phase and cumulative.<br />
★ Active, reactive, apparent energy, by phase and cumulative.<br />
★ Transformer K factor.<br />
★ Power factors (PF) and displacement factors (DPF or COSΦ).<br />
★ Short-term voltage flicker (PST).<br />
★ Three phase unbalance(current and voltage).</p>
<p></span></p>
<div style="margin:0px;padding:0px">
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">2. Transientcapture function</b></p>
<p>Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctuations, voltage<br />
current surge, sag and short supply interruption, temporary overvoltage, impact current and Current voltage instantaneous<br />
distortion. Instruments can store 150 sets of transient waveform at the same time.</p>
<p></span>
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">3. Starting current monitoring</b></p>
<p>Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity.<br />
Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4<br />
channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and<br />
waveform curve of each cycle in 100s.</p>
<p></span>
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">4. Trend chart recording and storing function</b></p>
<p>Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf,<br />
Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a<br />
long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).</p>
<p></span>
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">5. Alarm function</b></p>
<p>Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as:<br />
voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distortion. You can configure 40 different<br />
alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit<br />
values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.</p>
<p></span>
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">6. Snapshot function</b></p>
<p>Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage<br />
and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.</p>
<p></span>
</div>
<div style="margin:0px;padding:0px"><span style="margin:0px;padding:0px"><br />
<b style="margin: 0px;padding: 0px">7. Communication function</b></p>
<p>Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the tran</span></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1047</post-id>	</item>
		<item>
		<title>Sensor punto de rocio para aire comprimido con display</title>
		<link>https://tienda.softbi.com.mx/producto/sensor-punto-de-rocio-para-aire-comprimido-con-display/</link>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 19:26:56 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1011</guid>

					<description><![CDATA[&#160; Product Name On Line Dew Point Meter Item NO. Fm950 Probe technical indicators Measurement parameters Measuring range typical Output Analog output 0··1V Digital interface UART Linear voltage output 0…1V   -80~+60℃td Technical Parameters Operating humidity range ±0.8%RH      0~100%RH Working dew point range ±2℃Td       -60~+60℃td Repeatability &#60;0.5%RH ;&#60;0.1℃ Year drift &#60;1%RH;&#60;0.1℃ Response time T63 3-12 seconds [...]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td valign="center" width="227" data-spm-anchor-id="a2700.details.0.i31.26904b31o5zco4">Product Name</td>
<td valign="center" width="292">On Line Dew Point Meter</td>
</tr>
<tr>
<td valign="center" width="227">Item NO.</td>
<td valign="center" width="292">Fm950</td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Probe technical indicators</strong></td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Measurement parameters</strong></td>
</tr>
<tr>
<td valign="top" width="227">Measuring range</td>
<td valign="top" width="292">typical</td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="227">Analog output</td>
<td valign="top" width="292">0··1V</td>
</tr>
<tr>
<td valign="top" width="227">Digital interface</td>
<td valign="top" width="292">UART</td>
</tr>
<tr>
<td valign="top" width="227">Linear voltage output</td>
<td valign="top" width="292">0…1V   -80~+60℃td</td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Technical Parameters</strong></td>
</tr>
<tr>
<td valign="top" width="227">Operating humidity range</td>
<td valign="top" width="292">±0.8%RH      0~100%RH</td>
</tr>
<tr>
<td valign="top" width="227">Working dew point range</td>
<td valign="top" width="292">±2℃Td       -60~+60℃td</td>
</tr>
<tr>
<td valign="top" width="227">Repeatability</td>
<td valign="top" width="292">&lt;0.5%RH ;&lt;0.1℃</td>
</tr>
<tr>
<td valign="top" width="227">Year drift</td>
<td valign="top" width="292">&lt;1%RH;&lt;0.1℃</td>
</tr>
<tr>
<td valign="top" width="227">Response time</td>
<td valign="top" width="292">T63 3-12 seconds</td>
</tr>
<tr>
<td valign="top" width="227">Probe pressure</td>
<td valign="top" width="292">20bar</td>
</tr>
<tr>
<td valign="top" width="227">Probe type</td>
<td valign="top" width="292">stainless steel</td>
</tr>
<tr>
<td valign="top" width="227">Probe grade</td>
<td valign="top" width="292">IP65(NEMA4)</td>
</tr>
<tr>
<td valign="top" width="227">Probe cable</td>
<td valign="top" width="292">2 meters</td>
</tr>
<tr>
<td valign="top" width="227">Standard threaded interface</td>
<td valign="top" width="292">G1 / 2 316 stainless steel</td>
</tr>
<tr>
<td valign="top" width="227">CE certification</td>
<td valign="top" width="292">CE-2007/108/EG</td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Instrument Specifications</strong></td>
</tr>
<tr>
<td valign="top" width="227">Display the parameters</td>
<td valign="top" width="292">Dew point ℃ td</td>
</tr>
<tr>
<td valign="top" width="227"></td>
<td valign="top" width="292">Micro Water PPMV</td>
</tr>
<tr>
<td valign="top" width="227">Instrument output function</td>
<td valign="top" width="292">4-20mA/0-10V</td>
</tr>
<tr>
<td valign="top" width="227"></td>
<td valign="top" width="292">RS485 / RS232 communication</td>
</tr>
<tr>
<td valign="top" width="227"></td>
<td valign="top" width="292">Relay alarm output</td>
</tr>
<tr>
<td colspan="2" valign="top" width="519"><strong>Other parameters</strong></td>
</tr>
<tr>
<td valign="top" width="227">power supply</td>
<td valign="top" width="292">24-220VDC/AC</td>
</tr>
<tr>
<td valign="top" width="227">Auxiliary function</td>
<td valign="top" width="292">Range arbitrarily set, zero correction</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><img decoding="async" src="https://sc02.alicdn.com/kf/HTB1r6bDQFXXXXamapXXq6xXFXXXW/230296112/HTB1r6bDQFXXXXamapXXq6xXFXXXW.jpg" alt="Fm950 dew point transmitter with Vaisala online dew point meter" /></p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1011</post-id>	</item>
		<item>
		<title>Portable 3 Phase Power Quality Analyzer Harmonics</title>
		<link>https://tienda.softbi.com.mx/producto/roktools-portable-3-phase-power-quality-analyzer-harmonics/</link>
					<comments>https://tienda.softbi.com.mx/producto/roktools-portable-3-phase-power-quality-analyzer-harmonics/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 21:37:56 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=803</guid>

					<description><![CDATA[Specifications &#160; Measurement Range Resolution Accuracy Voltage/Current/Frequency Channel 3-phase line input + 1 neutral line input Vrms(dc+ac) 1 ~ 1000Vrms 0.1Vrms ±5% Vpk 1 ~ 1400Vpk 0.1Vpk ±5% V(CF) 1.0 ~ &#62;2.8 0.01 ±5% Arms 1~ 3000A 1A ±1% ± 5digits 1~ 300A 0.1A ±1% ± 5digits Apk 1 ~ 4000Apk 1A ±1% ± 5digits [...]]]></description>
										<content:encoded><![CDATA[<p><strong>Specifications</strong></p>
<p>&nbsp;</p>
<table style="height: 2924px;" border="1" width="553" cellspacing="0" cellpadding="0">
<tbody>
<tr align="left">
<td></td>
<td>Measurement Range</td>
<td>Resolution</td>
<td>Accuracy</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Voltage/Current/Frequency</td>
<td></td>
</tr>
<tr align="left">
<td>Channel</td>
<td colspan="3">3-phase line input + 1 neutral line input</td>
<td></td>
</tr>
<tr align="left">
<td>Vrms(dc+ac)</td>
<td>1 ~ 1000Vrms</td>
<td>0.1Vrms</td>
<td>±5%</td>
<td></td>
</tr>
<tr align="left">
<td>Vpk</td>
<td>1 ~ 1400Vpk</td>
<td>0.1Vpk</td>
<td>±5%</td>
<td></td>
</tr>
<tr align="left">
<td>V(CF)</td>
<td>1.0 ~ &gt;2.8</td>
<td>0.01</td>
<td>±5%</td>
<td></td>
</tr>
<tr align="left">
<td rowspan="2">Arms</td>
<td>1~ 3000A</td>
<td>1A</td>
<td>±1% ± 5digits</td>
<td></td>
</tr>
<tr align="left">
<td>1~ 300A</td>
<td>0.1A</td>
<td>±1% ± 5digits</td>
<td></td>
</tr>
<tr align="left">
<td>Apk</td>
<td>1 ~ 4000Apk</td>
<td>1A</td>
<td>±1% ± 5digits</td>
<td></td>
</tr>
<tr align="left">
<td>A(CF)</td>
<td>1 ~ 10</td>
<td>0.01</td>
<td>±5%</td>
<td></td>
</tr>
<tr align="left">
<td rowspan="2">Frequency</td>
<td>42.5~57.5Hz(50Hz nominal)</td>
<td>0.01Hz</td>
<td>±0.01%</td>
<td></td>
</tr>
<tr align="left">
<td>51~69Hz(60Hz nominal)</td>
<td>0.01Hz</td>
<td>±0.01%</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Dips &amp; Swells</td>
<td></td>
</tr>
<tr align="left">
<td>Vrms1/2</td>
<td>0 ~ 200% of nominal voltage</td>
<td>0.1Vrms</td>
<td>±1%</td>
<td></td>
</tr>
<tr align="left">
<td rowspan="2" valign="top">Arms1/2</td>
<td>1 ~ 3000A</td>
<td>1A</td>
<td>±1% ±5 counts</td>
<td></td>
</tr>
<tr align="left">
<td>1 ~ 300A</td>
<td>0.1A</td>
<td>±1% ±5 counts</td>
<td></td>
</tr>
<tr align="left">
<td valign="top">Threshold levels</td>
<td colspan="3">Programmable thresholds in percent of nominal voltage<br />
Event detection based upon ½ cycle rms voltages<br />
Captures Dips, Swells Interruptions and Rapid Voltage Changes</td>
<td></td>
</tr>
<tr align="left">
<td>Duration</td>
<td>hhh,mm,ss,mmm</td>
<td>0.5 cycle</td>
<td>1 cycle</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Harmonic</td>
<td></td>
</tr>
<tr align="left">
<td>Harmonic Order</td>
<td>1 ~ 50</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr align="left">
<td>Inter-Harmonic Order</td>
<td>1 ~ 49</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr align="left">
<td>Voltage</td>
<td>0.0 ~ 100.0%</td>
<td>0.1%</td>
<td>±0.1% ± nx0.1%</td>
<td></td>
</tr>
<tr align="left">
<td>Current</td>
<td>0.0 ~ 100.0%</td>
<td>0.1%</td>
<td>±0.1% ± nx0.1%</td>
<td></td>
</tr>
<tr align="left">
<td>THD</td>
<td>0.0 ~ 100.0%</td>
<td>0.1%</td>
<td>±2.5%</td>
<td></td>
</tr>
<tr align="left">
<td>DC Relative</td>
<td>0.0 ~ 100.0%</td>
<td>0.1%</td>
<td>±2%</td>
<td></td>
</tr>
<tr align="left">
<td>Frequency</td>
<td>0 ~ 3500Hz</td>
<td>1Hz</td>
<td>1Hz</td>
<td></td>
</tr>
<tr align="left">
<td>Phase</td>
<td>-360° ~ 0°</td>
<td>1°</td>
<td>± nx1.5°</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Power And Energy</td>
<td></td>
</tr>
<tr align="left">
<td rowspan="2" valign="top">Active Power/Apparent Power/Reactive Power</td>
<td rowspan="2" valign="top">1.0 ~ 20.00MW</td>
<td rowspan="2" valign="top">0.1kW</td>
<td rowspan="2" valign="top">±1.5±10 counts</td>
<td></td>
</tr>
<tr align="left">
<td></td>
</tr>
<tr align="left">
<td>Energy</td>
<td>0.00kWh ~ 200GWh</td>
<td>10Wh</td>
<td>±1.5±10 counts</td>
<td></td>
</tr>
<tr align="left">
<td>Power Factor</td>
<td>0 ~ 1</td>
<td>0.01</td>
<td>±0.03</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Flicker</td>
<td></td>
</tr>
<tr align="left">
<td>Pst(1min),Pst,Plt,PF5</td>
<td>0.00 ~ 20.00</td>
<td>0.01</td>
<td>±5%</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Unbalance</td>
<td></td>
</tr>
<tr align="left">
<td>Voltage</td>
<td>0.0 ~ 5.0%</td>
<td>0.1%</td>
<td>±0.5%</td>
<td></td>
</tr>
<tr align="left">
<td>Current</td>
<td>0.0 ~ 20.0%</td>
<td>0.1%</td>
<td>±1%</td>
<td></td>
</tr>
<tr align="left">
<td>Voltage Phase Angle</td>
<td>-360° ~ 0°</td>
<td>1°</td>
<td>±2digits</td>
<td></td>
</tr>
<tr align="left">
<td>Current Phase Angle</td>
<td>-360° ~ 0°</td>
<td>1°</td>
<td>±5digits</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Voltage Transient</td>
<td></td>
</tr>
<tr align="left">
<td>Vpk</td>
<td>±6000Vpk</td>
<td>1V</td>
<td>±15%</td>
<td></td>
</tr>
<tr align="left">
<td>Vrms</td>
<td>10 ~ 1000Vrms</td>
<td>1V</td>
<td>±2.5%</td>
<td></td>
</tr>
<tr align="left">
<td>Min. Tested Time</td>
<td colspan="3">50us</td>
<td></td>
</tr>
<tr align="left">
<td>Sampling Rate</td>
<td colspan="3">20kS/s</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Inrush Current</td>
<td></td>
</tr>
<tr align="left">
<td>Arms(AC+DC)</td>
<td>0~3000Arms</td>
<td>0.1</td>
<td>±1% ± 5digits</td>
<td></td>
</tr>
<tr align="left">
<td>Inrush Duration</td>
<td>6s ~ 32min selectable</td>
<td>10ms</td>
<td>±20ms</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">Logger</td>
<td></td>
</tr>
<tr align="left">
<td valign="top">Recording</td>
<td colspan="3">Parameter, duration time and time interval can be set by user, which can be export on PC</td>
<td></td>
</tr>
<tr align="left">
<td>Memory</td>
<td colspan="3">8G</td>
<td></td>
</tr>
<tr align="left">
<td>Max. recording time</td>
<td colspan="3">1 year</td>
<td></td>
</tr>
<tr align="left">
<td colspan="4">System Monitor</td>
<td></td>
</tr>
<tr align="left">
<td valign="top">Parameters</td>
<td colspan="3">Vrms,Arms,Harmonic Volts,THD Volts,Plt,Vrms1/2,Arms1/2,Vneg,Hz,dips and swells, unbalance</td>
<td></td>
</tr>
<tr align="left">
<td>Record Time</td>
<td colspan="3">2h ~ 7days</td>
<td></td>
</tr>
<tr align="left">
<td>Record Event Number</td>
<td colspan="3">&gt;10000</td>
<td></td>
</tr>
<tr align="left">
<td>Limits</td>
<td colspan="3">According EN50160 or customer definable</td>
<td></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/roktools-portable-3-phase-power-quality-analyzer-harmonics/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">803</post-id>	</item>
		<item>
		<title>Analizador de calidad de energía avanzado ES4000</title>
		<link>https://tienda.softbi.com.mx/producto/analizador-de-calidad-de-energia-del-instrumento-de-analisis-y-medicion-de-la-calidad-de-la-energia-electrica-avanzado-es4000/</link>
					<comments>https://tienda.softbi.com.mx/producto/analizador-de-calidad-de-energia-del-instrumento-de-analisis-y-medicion-de-la-calidad-de-la-energia-electrica-avanzado-es4000/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 21:24:23 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=801</guid>

					<description><![CDATA[Descripción del producto 1. Función de prueba ★ Pantalla de forma de onda en tiempo real (voltaje de 4 canales / corriente de 4 canales). ★ Valores eficaces verdaderos de tensiones y corrientes. ★ Los componentes de CC de los voltajes. ★ Valores máximos de corriente y tensión. ★ Valores de voltaje y corriente RMS [...]]]></description>
										<content:encoded><![CDATA[<div class="J_module">
<div id="ali-anchor-AliMagic-v1bakl" class="magic-0" data-section="AliMagic-v1bakl" data-section-title="Product Description">Descripción del producto</div>
</div>
<div class="J_module">
<div class="detail-decorate-json-renderer-container">
<div class="magic-1">
<div class="magic-2">
<div class="magic-3">
<div class="magic-4"><b>1. Función de prueba<br />
</b><br />
★ Pantalla de forma de onda en tiempo real (voltaje de 4 canales / corriente de 4 canales).<br />
★ Valores eficaces verdaderos de tensiones y corrientes.<br />
★ Los componentes de CC de los voltajes.<br />
★ Valores máximos de corriente y tensión.<br />
★ Valores de voltaje y corriente RMS mínimos y máximos de medio ciclo.<br />
★ Visualización del diagrama de Pharos.<br />
★ Medición de cada armónico hasta el orden 50.<br />
★ Los gráficos de barras muestran las relaciones armónicas de corriente y voltaje de cada fase.<br />
★ Distorsión armónica total (THD).<br />
★ Potencia activa, reactiva, aparente, por fase y acumulativa.<br />
★ Energía activa, reactiva, aparente, por fase y acumulativa.<br />
★ Factor K del transformador.<br />
★ Factores de potencia (PF) y factores de desplazamiento (DPF o COSΦ).<br />
★ Parpadeo de voltaje a corto plazo (PST).<br />
★ Desequilibrio trifásico (corriente y voltaje).</p>
<div></div>
<div><b><br />
2. Función de captura transitoria</b>Supervisión del cambio instantáneo de los parámetros de corriente de voltaje de la red eléctrica, incluidas las fluctuaciones de corriente de voltaje, sobretensión de<br />
corriente de voltaje , caída y corte de suministro, sobretensión temporal, corriente de impacto y<br />
distorsión instantánea de voltaje de corriente . Los instrumentos pueden almacenar 150 conjuntos de formas de onda transitorias al mismo tiempo.</div>
<div><b>3.</b>Monitoreo de la corriente de inicio El monitoreo de la sobretensión de la línea y la corriente de inicio cuando el equipo eléctrico se está iniciando, ayuda a diseñar correctamente la capacidad.<br />
Se puede mostrar la curva RMS ascendente / descendente En el proceso de inicio, la curva envolvente de la corriente de inicio, la forma de onda de la<br />
corriente de 4 canales y la tensión de 4 canales. Graba alrededor de 100 segundos después del disparo, almacena la corriente / voltaje instantáneo y la<br />
curva de forma de onda de cada ciclo en 100 segundos.</div>
<div><b>4. Función de registro y almacenamiento de gráficos de tendencias</b>Almacene todos los parámetros de prueba de las funciones de prueba básicas (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf,<br />
Aunb, KF, W, VAR, VA, PF, COSφ, TANφ), 50 armónicos de tensión, 50 armónicos de corriente. Y crea la curva de tendencia. Registre datos durante<br />
mucho tiempo según las necesidades (selección simultánea de 20 parámetros para registrar datos una vez cada cinco segundos, puede registrar aproximadamente 300 días).</div>
<div><b>5. Función de alarma</b>Establezca los valores límite de acuerdo a las necesidades, monitoreando los valores si sobreimpulso, si sobreimpulso generará un registro de alarma, tales como:<br />
voltaje, corriente, desequilibrio, relación armónica, frecuencia, potencia activa, distorsión armónica total. Puede configurar 40<br />
alarmas diferentes , cada grupo puede establecer diferentes parámetros de monitoreo (incluidos 50 armónicos, un total de 123 parámetros diferentes) y<br />
valores límite , también puede establecer el tiempo más corto de sobreimpulso. El registro puede contener hasta 12,800 alarmas.</div>
<div><b>6. Función de instantánea</b>Se puede guardar cualquier pantalla (instantánea de pantalla), al mismo tiempo registra automáticamente la hora y el modo de prueba. Tales como pueden guardar voltaje<br />
y forma de onda de corriente, gráfico de barras armónicas, diagrama fasorial, etc. Puede guardar un máximo de 60 instantáneas de pantalla.</div>
<div><b>7. Función de</b>comunicación Comunicarse con la computadora a través de USB; El software de monitoreo puede mostrar la forma de onda del análisis de la calidad de la energía, leer la<br />
forma de onda transitoria , registrar el gráfico de tendencias, el registro de alarmas, capturas de pantalla y mostrar en la computadora.</div>
<div><b>8. Función de ajuste</b>El usuario puede configurar la hora y la fecha, configurar el contraste y el brillo de la pantalla, definir los<br />
colores de la curva de cada fase .<br />
Elección del tipo de conexión a la red.<br />
Configuración del tipo de sensores de corriente y relaciones de voltaje.<br />
Seleccione menú chino o menú inglés.</div>
<div>
<p><b>9. Menú de ayuda en chino / inglés En</b>cada etapa de la operación puede presionar la tecla «ayuda» para obtener información relevante.</p>
</div>
<div></div>
<div></div>
<div></div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="J_module">
<div class="ife-detail-decorate-table">
<table class="has-title hight-light-first-column all magic-5" style="height: 1359px;" width="562">
<tbody>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-6"><b>Medición</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-7"><b>Rango</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-8"><b>Resolución de pantalla</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-9"><b>El error máximo en el rango de la referencia.</b></div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-6"><b>Frecuencia</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-7">40 Hz ~ 70 Hz</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-8">0,01 Hz</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-9">± (0,03) Hz</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-6"><b>Verdadero voltaje RMS fase a neutro</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-7">1.0V ~ 1000V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-8">Resolución mínima 0,1 V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-9">± (0,5% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Verdadero voltaje RMS fase a fase</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">1.0V ~ 2000V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 0,1 V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (0,5% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Voltaje DC</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">1.0V ~ 1000V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 0,1 V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.0% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Corriente RMS verdadera</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">10mA ~ 6000A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 1 mA</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (0,5% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Pico de voltaje de fase a neutro</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">1.0V ~ 1414V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 0,1 V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.0% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Pico de voltaje de fase a fase</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">1.0V ~ 2828V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 0,1 V</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.0% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Pico actual</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">10mA ~ 8484A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 1 mA</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.0% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6">
<div class="magic-14"><b>Factor pico</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">1,00 ~ 3,99</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">0,01</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 2 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-11">4,00 ~ 9,99</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">0,01</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (5% + 2 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Poder activo</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-11">0.000W ~ 9999.9kW</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-8">Resolución mínima 0,001 W</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 3dgt)<br />
Cosφ≥0,8</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.5% + 10dgt)<br />
0.2≤Cosφ &lt;0.8</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Potencia reactiva, inductiva o capacitiva</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-11">0.000VAR ~<br />
9999.9kVAR</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-8">Resolución mínima 0.001VAR</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 3dgt)<br />
Sinφ≥0.5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.5% + 10dgt)<br />
0.2≤Sinφ &lt;0.5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-6"><b>Poder aparente</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-7">0.000VA ~<br />
9999.9kVA</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-8">Resolución mínima 0.001VA</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-9">± (1% + 3dgt)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Factor de potencia</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-11">-1.000 ~ 1.000</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-8">0,001</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1,5% + 3dgt)<br />
Cosφ≥0,5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.5% + 10dgt)<br />
0.2≤Cosφ &lt;0.5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Energia activa</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-7">0.000Wh ~ 9999.9MWh</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-12">Resolución mínima 0,001 Wh</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 3dgt)<br />
Cosφ≥0,8</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.5% + 10dgt)<br />
0.2≤Cosφ &lt;0.8</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Energía reactiva, inductiva o capacitiva</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-7">0.000VARh ~ 9999.9MVARh</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-12">Resolución mínima 0.001VARh</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 3dgt)<br />
Sinφ≥0.5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1.5% + 10dgt)<br />
0.2≤Sinφ &lt;0.5</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Energía de los padres</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">0.000VAh ~ 9999.9MVAh</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">Resolución mínima 0.001VAh</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (1% + 3dgt)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Ángulo de fase</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-11">-179 ° ~ 180 °</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-12">1 °</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-13">± (2 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Tanφ<br />
(VA ≥ 50 VA)</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">-32,76 ~ 32,76</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">Resolución mínima 0,001</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">φ: ± (1 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Cambio de fase del factor de potencia (DPF)</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">-1.000 ~ 1.000</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,001</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">φ: ± (1 °</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Relación de armónicos<br />
(orden 1 a 50) (Vrms&gt; 50V)</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">0,0% ~ 99,9%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,1%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (1% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6"><b>Ángulo armónico<br />
(Vrms&gt; 50 V)</b></div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-7">-179 ° ~ 180 °</div>
</td>
<td colspan="1" rowspan="2">
<div class="magic-12">1 °</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (3 °) armónicos de orden 1 a 25</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-20">± (10 °) armónicos de orden 26 a 50</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Relación armónica total<br />
(THD o THD-F) ≤50</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">0,0% ~ 99,9%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,1%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (1% + 5 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Factor de distorsión<br />
(DF o THD-R) ≤50</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">0,0% ~ 99,9%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,1%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (1% + 10 dígitos)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Factor K del transformador</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">1,00 ~ 99,99</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,01</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (5%)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-10"><b>Desequilibrio de 3 fases</b></div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-18">0,0% ~ 100%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-19">0,1%</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-20">± (1%)</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="J_module">
<div class="ife-detail-decorate-table" data-spm-anchor-id="0.wholesale.0.i32.3208658cMD8KxH">
<table class="has-title hight-light-first-column all magic-5" style="height: 133px;" width="638">
<tbody>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-6">
<div class="magic-21" data-spm-anchor-id="0.0.0.i22.688f4f0522LviA"><span class="magic-22" style="font-family: Arial;"><b data-spm-anchor-id="0.0.0.i31.688f4f0522LviA">Tipo de sensor de corriente</b></span></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">
<div class="magic-21" data-spm-anchor-id="0.0.0.i25.688f4f0522LviA"><b>Corriente RMS verdadera</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">
<div class="magic-21" data-spm-anchor-id="0.0.0.i33.688f4f0522LviA"><b>Error máximo de la corriente RMS verdadera</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-6">
<div class="magic-21" data-spm-anchor-id="0.0.0.i35.688f4f0522LviA"><b>Error máximo de ángulo de faseφ</b></div>
</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6">
<div class="magic-21" data-spm-anchor-id="0.0.0.i53.688f4f0522LviA"><b>Pinza amperimétrica FR008</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">10mA ~ 99mA</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-25">± (1,5 °), brazos ≥ 20 mA</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-24">100mA ~ 10.0A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-25">± (1 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6">
<div class="magic-21"><b>Pinza amperimétrica FR020</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">0,10 A ~ 0,99 A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-25">± (1,5 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-24">1,00 A ~ 100 A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-25">± (1 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6">
<div class="magic-21"><b>Pinza amperimétrica FR050</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">1.0A ~ 9.9A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">± (2% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-6">± (3 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-23">10.0A ~ 1000A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">± (2% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-6">± (2 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="2">
<div class="magic-6">
<div class="magic-21"><b>Sensor de corriente de bobina flexible FR300R (con integrador)</b></div>
</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">10A ～ 199A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-23">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-6">± (3 °)</div>
</td>
</tr>
<tr>
<td colspan="1" rowspan="1">
<div class="magic-24">200A ~ 6000A</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-24">± (1% + 3dgt)</div>
</td>
<td colspan="1" rowspan="1">
<div class="magic-25">± (2 °)</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/analizador-de-calidad-de-energia-del-instrumento-de-analisis-y-medicion-de-la-calidad-de-la-energia-electrica-avanzado-es4000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">801</post-id>	</item>
		<item>
		<title>Three Phase Power quality Analyzer GDPQ-300E</title>
		<link>https://tienda.softbi.com.mx/producto/portable-three-phase-power-quality-analyzer-gdpq-300e-with-good-price/</link>
					<comments>https://tienda.softbi.com.mx/producto/portable-three-phase-power-quality-analyzer-gdpq-300e-with-good-price/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 21:19:54 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=799</guid>

					<description><![CDATA[Product Description Portable Three Phase Power quality Analyzer  GDPQ-300E With Good Price GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality.           It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis.              Meanwhile, it [...]]]></description>
										<content:encoded><![CDATA[<div id="ali-anchor-AliPostDhMb-igasw" class="mceSectionContainer" data-section="AliPostDhMb-igasw" data-section-title="Product Description">
<div id="ali-title-AliPostDhMb-igasw">Product Description</div>
</div>
<div></div>
<div id="ali-anchor-AliPostDhMb-igasw" class="mceSectionContainer" data-section="AliPostDhMb-igasw" data-section-title="Product Description">
<div><strong>Portabl</strong><strong>e Three Phase Power quality Analyzer  GDPQ-300E With Good Price</strong></div>
<div>GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality.           It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis.              Meanwhile, it equips with data analysis software, by which the measure data can be uploaded to PC.</div>
<div></div>
</div>
<div id="ali-anchor-AliPostDhMb-f4p2b" class="mceSectionContainer" data-section="AliPostDhMb-f4p2b" data-section-title="Features">
<div id="ali-title-AliPostDhMb-f4p2b">Features</div>
<div>
<ul>
<li>ARM and DSP, 16M byte memory.</li>
<li>Touch screen, more easy and convenient.</li>
<li>Data measure and saving, can be uploaded to PC.</li>
<li>Module structure, reasonable design and reliable operation.</li>
<li>Easy and convenient software upgrading.</li>
<li>Detailed analysis of measure data by power quality data analysis software in PC.</li>
</ul>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-45f58" class="mceSectionContainer" data-section="AliPostDhMb-45f58" data-section-title="Specifications">
<div id="ali-title-AliPostDhMb-45f58">Specifications</div>
<div>
<table style="height: 874px;" border="1" width="682" cellspacing="0">
<tbody>
<tr>
<td valign="center">
<p align="center">No.</p>
</td>
<td valign="center">
<p align="center">Items</p>
</td>
<td valign="center">
<p align="center">Description</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">1</p>
</td>
<td valign="center">
<p align="center">Volt/Amps/Hertz</p>
</td>
<td valign="center">
<p align="justify">Measure three phase voltage, zero line voltage, three phase current, zero line current, frequency. Displays RMS value, peak value, wave/peak ratio, waveform chart, trend chart, etc.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">2</p>
</td>
<td valign="center">
<p align="center">Harmonics</p>
</td>
<td valign="center">
<p align="justify">Measure the fundamental wave of voltage and current and the 2nd to 50th harmonics. The measurement results include harmonic RMS, harmonic content, and total harmonic distortion (THD); displays histograms, trend charts, etc.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">3</p>
</td>
<td valign="center">
<p align="center">Inter-harmonics</p>
</td>
<td valign="center">
<p align="justify">Measure 0.1 ~ 19.9th inter-harmonics of voltage and current, and the measurement results include the RMS values of the inter-harmonic components and subgroups, the inter-harmonic content rate, etc .; can display histograms, trend charts, etc.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">4</p>
</td>
<td valign="center">
<p align="center">Power &amp; Energy</p>
</td>
<td valign="center">
<p align="justify">Measure the apparent power (electric energy), active power (electric energy), reactive power (electric energy), power factor, etc. of 3P4W/ 3P3W; can display the trend chart, and measure the demand of 1, 5, 10, 15, 30, 60 minutes.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">5</p>
</td>
<td valign="center">
<p align="center">Unbalance</p>
</td>
<td valign="center">
<p align="justify">Measure the positive sequence component, negative sequence component, zero sequence component, negative sequence unbalance degree and zero sequence unbalance degree of voltage and current of 3P4W / 3P3W electrical system, and display the phase angle, vector diagram and trend diagram of three-phase voltage and current.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">6</p>
</td>
<td valign="center">
<p align="center">Monitor</p>
</td>
<td valign="center">
<p align="justify">Long-term recording of steady-state power quality parameters, including voltage/current/frequency, harmonics, power, three-phase unbalance, fluctuation/flicker, and the recording time interval can be adjusted from 3 seconds to 30 minutes.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">7</p>
</td>
<td valign="center">
<p align="center">Flicker</p>
</td>
<td valign="center">
<p align="justify">1 minute flicker, 10 minutes short-time flicker, 2 hours long-time flicker measurement.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">8</p>
</td>
<td valign="center">
<p align="center">Dips &amp; Swells</p>
</td>
<td valign="center">
<p align="justify">Detect and record voltage swell, sag and interruption events.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">9</p>
</td>
<td valign="center">
<p align="center">Inrush</p>
</td>
<td valign="center">
<p align="justify">Detect and record surge current events.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">10</p>
</td>
<td valign="center">
<p align="center">Harmonic Power</p>
</td>
<td valign="center">
<p align="justify">Detect 2-30 times harmonic power, display histogram, trend chart, etc.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">11</p>
</td>
<td valign="center">
<p align="center">Power Wave</p>
</td>
<td valign="center">
<p align="justify">According to the set time (1-5 minutes), measure the rapid change of power (active, reactive, apparent power).</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">12</p>
</td>
<td valign="center">
<p align="center">Transient</p>
</td>
<td valign="center">
<p align="justify">Detection of voltage transient events over 20 microseconds.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">13</p>
</td>
<td valign="center">
<p align="center">Oscilloscope</p>
</td>
<td valign="center">
<p align="justify">Used to view the voltage/current signal waveform.</p>
</td>
</tr>
<tr>
<td valign="center">
<p align="center">14</p>
</td>
<td valign="center">
<p align="center">System</p>
</td>
<td valign="center">
<p align="justify">Data management, system setting, 3 phase color setting, angle setting, version information.</p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>Other technical parameters</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<table style="height: 358px;" border="1" width="308">
<tbody>
<tr>
<td>Voltage signal input loop</td>
<td>Direct access,input impedance: 1MΩ, 20pF</p>
<p>Measure range: voltage effective value 1000V</p>
<p>Power consumption: less than 0.5VA/phase</td>
</tr>
<tr>
<td>Current input loop</td>
<td>Indirect access</p>
<p>&nbsp;</p>
<p>Measure range: Current effective value 1A,5A,10A,100A,500A,1000A,3000A</p>
<p>(select corresponding current sensor)</p>
<p>&nbsp;</p>
<p>Power consumption: Less than 0.5VA/phase</td>
</tr>
<tr>
<td>Measure signal frequency range</td>
<td>40Hz-70Hz</td>
</tr>
<tr>
<td>Display screen</td>
<td>5.7Inch, 640*480 color LCD with touch screen</td>
</tr>
<tr>
<td>Memory storage</td>
<td>128M byte FLASH</td>
</tr>
<tr>
<td>Outside storage port</td>
<td>USA( plug in USB disk)</td>
</tr>
<tr>
<td>Working power supply</td>
<td data-spm-anchor-id="a2700.details.pronpeci14.i0.40081090O0W3wR">Rechargeable Li-battery,5-6hours working time for full charge</td>
</tr>
<tr>
<td>Power supply</td>
<td> AC100-240V/DC 16.8V-1A power adapter/charger</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/portable-three-phase-power-quality-analyzer-gdpq-300e-with-good-price/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">799</post-id>	</item>
		<item>
		<title>3 phases multifunction panel power meter with profibus SD harmonics APM801</title>
		<link>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/</link>
					<comments>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 20:49:48 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=796</guid>

					<description><![CDATA[General APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have ful power measurement, energy Istatistics, analysis of power qualify and network commlyications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network. [...]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/H1ce637584eee44f3b3ffa673ee230fd50/200461481/H1ce637584eee44f3b3ffa673ee230fd50.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="461" height="49" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-spm-anchor-id="a2700.wholesale.pronpeci14.i0.57d5371cENIxMy" /></p>
<p><strong>General</strong></p>
<table style="height: 5px;" border="1" width="327" data-mce-background-color="#ffffff">
<tbody>
<tr>
<td>APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology.<br />
APM series meters have ful power measurement, energy Istatistics, analysis of power qualify and network commlyications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Appearance</strong></p>
<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/Hbdfd55db27cd40088eb6dfcc192831c6A/200461481/Hbdfd55db27cd40088eb6dfcc192831c6A.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="119" height="119" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="228" data-height="228" /><img loading="lazy" decoding="async" class="" src="https://sc02.alicdn.com/kf/H00f032563f934544a813e55fe144c517j/200461481/H00f032563f934544a813e55fe144c517j.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="168" height="168" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="234" data-height="234" /><img loading="lazy" decoding="async" class="" src="https://sc02.alicdn.com/kf/H9e0e41314367406a863e7025ccd28aa6L/200461481/H9e0e41314367406a863e7025ccd28aa6L.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="158" height="158" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="230" data-height="230" /></p>
<p>&nbsp;</p>
<p><strong>Product Function</strong></p>
<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/Haf48b3207fb842b5bf0da23076c7235eT/200461481/Haf48b3207fb842b5bf0da23076c7235eT.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="361" height="243" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="751" data-height="507" /><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/H41c85d36fb8f43c89d60c46bf8f9de24c/200461481/H41c85d36fb8f43c89d60c46bf8f9de24c.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="557" height="135" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="752" data-height="182" data-spm-anchor-id="a2700.wholesale.pronpeci14.i1.57d5371cENIxMy" /></p>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">796</post-id>	</item>
		<item>
		<title>Medidor multifuncional trifásico PM135 &#8211; Análisis de harmónicos</title>
		<link>https://tienda.softbi.com.mx/producto/medidor-de-potencia-trifasico-multifuncional-satec-pm135-rs485-con-calidad-de-potencia-y-analisis-de-armonicos/</link>
					<comments>https://tienda.softbi.com.mx/producto/medidor-de-potencia-trifasico-multifuncional-satec-pm135-rs485-con-calidad-de-potencia-y-analisis-de-armonicos/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 20:39:14 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=794</guid>

					<description><![CDATA[Descripción del producto El PM135 es un medidor de potencia trifásico multifuncional con medición de ingresos básica, calidad de energía y análisis de armónicos. El PM135 proporciona un sustituto rentable de numerosos medidores analógicos utilizados por clientes industriales, comerciales y de servicios públicos para la medición de energía básica. El PM135 está ampliamente integrado en [...]]]></description>
										<content:encoded><![CDATA[<div id="ali-title-AliPostDhMb-kakv7"><strong>Descripción del producto</strong></div>
<div>
<p>El PM135 es un medidor de potencia trifásico multifuncional con medición de ingresos básica, calidad de energía y análisis de armónicos.<br />
El PM135 proporciona un sustituto rentable de numerosos medidores analógicos utilizados por clientes industriales, comerciales y de servicios públicos para la medición de energía básica.<br />
El PM135 está ampliamente integrado en tableros de paneles y sistemas SCADA. Con la adición del módulo TOU exclusivo, el modelo EH responde a las necesidades de las aplicaciones de medición de ingresos. También es adecuado para la automatización de subestaciones de servicios públicos con su soporte de los protocolos estándar de la industria DNP 3.0, Modbus RTU e IEC 60870-5-101 / 104, así como sus capacidades de E / S (usando los módulos de Entrada / Salida Digital).<br />
La serie PM135 consta de dos modelos básicos que proporcionan mediciones digitales de más de 80 parámetros eléctricos localmente y más de 100 parámetros eléctricos a través de la interfaz RS-485.<br />
El PM135 tiene una pantalla LCD retroiluminada de 3&#215;2 ”/ 76&#215;49 mm, así como el indicador de carga de gráfico de barras exclusivo de SATEC.</p>
<p><strong><a>Características</a></strong></p>
<p>Rango de corriente hasta 200%</p>
<p>Armónicos de tensión y corriente individuales (hasta el 40)</p>
<p>Formas de onda 128 muestras / ciclo (a través de com.)</p>
<p>Supera la clase de precisión 0.5S</p>
<p>Funciones de alarma y control<br />
16 puntos de ajuste programables<br />
4 contadores<br />
Reloj en tiempo real<br />
Funciones de reloj y calendario integradas</p>
<p>Montaje en panel doble: Redondo de 4 ”; Cuadrado 96&#215;96 DIN</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/H69d2cf3f0e4b49e39e90a58da9037727W/205970117/H69d2cf3f0e4b49e39e90a58da9037727W.jpg_.webp" alt="SATEC PM135 multi-functional three-phase power meter RS485 with power quality and harmonics analysis" width="529" height="468" data-alt="SATEC PM135 multi-functional three-phase power meter RS485 with power quality and harmonics analysis" data-spm-anchor-id="a2700.details.pronpeci14.i0.32b36f93zvN5Uc" /></p>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/medidor-de-potencia-trifasico-multifuncional-satec-pm135-rs485-con-calidad-de-potencia-y-analisis-de-armonicos/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">794</post-id>	</item>
	</channel>
</rss>