<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Power meter multifunciones &#8211; Softbi</title>
	<atom:link href="https://tienda.softbi.com.mx/categoria-producto/medidores/power-meter-multifunciones/feed/" rel="self" type="application/rss+xml" />
	<link>https://tienda.softbi.com.mx</link>
	<description>Venta de equipo medición</description>
	<lastBuildDate>Wed, 03 Mar 2021 23:49:06 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://tienda.softbi.com.mx/wp-content/uploads/2021/01/cropped-xicon-softbi-32x32.png</url>
	<title>Power meter multifunciones &#8211; Softbi</title>
	<link>https://tienda.softbi.com.mx</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">190173959</site>	<item>
		<title>F-MPM110 Multifunction Electric Power Meter</title>
		<link>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/</link>
					<comments>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 23:49:05 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1070</guid>

					<description><![CDATA[Features Suit for LV/ HV Voltage System For low voltage system, direct connect up to 690 V (L-L) AC For high voltage system, support connect up to 65kV Ture-RMS Measuring Parameter True-RMS measuring parameters includes: U, I, P, Q, S, PF, F, kWh, kvarh, kVAh Demand Calculation 2 kinds of demand modes: fixed block and [...]]]></description>
										<content:encoded><![CDATA[<div>
<div id="o5si8">
<div id="ali-anchor-AliMaya-3xonw" data-section="AliMaya-3xonw" data-section-title="Features" data-spm-anchor-id="a2700.details.0.i30.70cf263f6Lhp1Z">Features</div>
</div>
<div>
<div id="it25d">
<p><b>Suit for LV/ HV Voltage System</b><br />
For low voltage system, direct connect up to 690 V (L-L) AC<br />
For high voltage system, support connect up to 65kV</p>
<p><b>Ture-RMS Measuring Parameter</b><br />
True-RMS measuring parameters includes:<br />
U, I, P, Q, S, PF, F, kWh, kvarh, kVAh</p>
<p><b>Demand Calculation</b><br />
2 kinds of demand modes: fixed block and rolling block</p>
<p><b>Power Quality Analysis</b><br />
31st Harmonic analysis, K factor, unbalance etc.</p>
<p><b>TOU (Multi-tariff billing), Historical Data of 31 Days and 12 Months</b><br />
TOU, 4 tariffs, 8 time period in 24 hours</p>
<p><b>Max./ Min. Record (U, I, P, Q*, S*)</b></p>
<p><b>Under/ Over Limit Alarm</b></p>
<p><b>64M Bit Memory, Build-in Web</b><br />
Real-time data inquiry by Web<br />
Save monitoring data (Time interval<br />
settable 1min, 5 min, 10min,15min, 30min)<br />
Support FTP for download memory data</p>
<p><b>CO2 (Carbon Dioxide) Calculation for kWh</b></p>
<p><b>Multiple Communication</b><br />
BACnet MS/TP Protocol (RS485 port)<br />
MODBUS-RTU Protocol (RS485 Port)<br />
MODBUS-TCP/IP Protocol (Ethernet port )</p>
<p><b>DI / DO</b></p>
<p><b>High Accuracy</b><br />
Active energy: according to IEC62053-22, class 0.5s<br />
Reactive energy: according to IEC62053-23, class 2</p>
</div>
</div>
</div>
<div>
<div id="nqgpt">
<div id="ali-anchor-AliMaya-gugr8" data-section="AliMaya-gugr8" data-section-title="Specification">Specification</div>
</div>
<div>
<div id="1isu5">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div><b>Basic Function</b></div>
</td>
</tr>
<tr>
<td rowspan="11">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<p>Real time metering</p></div>
</td>
<td>
<div>Voltage</div>
</td>
<td colspan="2">
<div>Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg</div>
</td>
</tr>
<tr>
<td>
<div>Current</div>
</td>
<td colspan="2">
<div>Ia, Ib, Ic, In, Iavg</div>
</td>
</tr>
<tr>
<td>
<div>Power</div>
</td>
<td colspan="2">
<div>Pa, Pb, Pc, ∑P, Qa, Qb, Qc, ∑Q, Sa, Sb,Sc, ∑S</div>
</td>
</tr>
<tr>
<td>
<div>Power Factor</div>
</td>
<td colspan="2">
<div>PFa, PFb, PFc, ∑PF</div>
</td>
</tr>
<tr>
<td>
<div>Energy</div>
</td>
<td colspan="2">
<div>kWh, kvarh, kVAh *</div>
</td>
</tr>
<tr>
<td>
<div>CO2 (Carbon dioxide)</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td>
<div>Frequency</div>
</td>
<td colspan="2">
<div>F</div>
</td>
</tr>
<tr>
<td>
<div>Demand &amp; Max. Demand</div>
</td>
<td colspan="2">
<div>Dmd_I, Dmd_P, Dmd_Q ,Dmd_S</div>
</td>
</tr>
<tr>
<td>
<div>Max./ Min. Value</div>
</td>
<td colspan="2">
<div>Max./ min. (U, I, P, Q*, S*)</div>
</td>
</tr>
<tr>
<td>
<div>Multi-tariff Energy *</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td>
<div>Phase Angle *</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td rowspan="5">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Power Quality Analysis</div>
</div>
</td>
<td>
<div>Unbalance</div>
</td>
<td colspan="2">
<div>U_unbl *, I_unbl *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic (31st )</div>
</td>
<td colspan="2">
<div>THDu, THDi, TOHDu, TOHDi, TEHDu, TEHDi, HRU *, RHI *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic RMS (0-31st )</div>
</td>
<td colspan="2">
<div>Harmonic RMS-U *, Harmonic RMS-I *, Harmonic RMS-P *</div>
</td>
</tr>
<tr>
<td>
<div>Harmonic energy (1st -13th )</div>
</td>
<td colspan="2">
<div></div>
</td>
</tr>
<tr>
<td colspan="3">
<div>Voltage crest factor, current K factor, Load rate, Voltage deviation, Frequency deviation<br />
Running time record for power-on period and qualified voltage &amp; current *</div>
</td>
</tr>
<tr>
<td>
<div>Setpoint Alarm</div>
</td>
<td colspan="3">
<div>Over/ under limit alarm</div>
</td>
</tr>
<tr>
<td>
<div>3DI +2 DO</div>
</td>
<td colspan="3">
<div>3 status input + 2 relay output</div>
</td>
</tr>
<tr>
<td>
<div>RS485</div>
</td>
<td colspan="3">
<div>Modbus-RTU protocol</div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>
<div>Record Function</div>
</div>
</td>
<td colspan="3">
<div>SOE (event log), Real-time clock ( yyyy-mm-dd hh:mm:ss) *</div>
</td>
</tr>
<tr>
<td colspan="3">
<div>Voltage/ frequency deviation, Voltage unbalance record</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="6j697">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div><b>Optional Module </b></div>
</td>
</tr>
<tr>
<td>
<div>SW</div>
</td>
<td>
<div>4 status input (wet contact)</div>
</td>
<td>
<div>LAN</div>
</td>
<td>
<div>64M bit memory + Ethernet TCP/IP</div>
</td>
</tr>
<tr>
<td>
<div>SD</div>
</td>
<td>
<div>4 status input (dry contact)</div>
</td>
<td>
<div>AI</div>
</td>
<td>
<div>2 analog input (4-20mA)</div>
</td>
</tr>
<tr>
<td>
<div>C *</div>
</td>
<td>
<div>The 2nd RS485</div>
</td>
<td>
<div>AO</div>
</td>
<td>
<div>2 analog output (4-20mA)</div>
</td>
</tr>
<tr>
<td>
<div>Ep *</div>
</td>
<td>
<div>2 pulse output</div>
</td>
<td>
<div>BA</div>
</td>
<td>
<div>BACnet MS/TP protocol</div>
</td>
</tr>
<tr>
<td>
<div>R</div>
</td>
<td>
<div>2 relay output</div>
</td>
<td>
<div></div>
</td>
<td>
<div></div>
</td>
</tr>
<tr>
<td colspan="4">
<div>* means some of function can&#8217;t be read through BACnet communication port</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="qf90d">
<table class="aliDataTable">
<tbody>
<tr>
<td>
<div><b>Parameter</b></div>
</td>
<td>
<div><b>Accuracy</b></div>
</td>
<td>
<div><b>Resolution</b></div>
</td>
<td>
<div><b>Measuring Range</b></div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>
<div></div>
<p>Voltage</p></div>
</td>
<td rowspan="2">
<div>
<div></div>
<p>0.2%</p></div>
</td>
<td rowspan="2">
<div>
<div></div>
<p>0.01V</p></div>
</td>
<td>
<div>Direct: 690Vph-ph</div>
</td>
</tr>
<tr>
<td>
<div>PT primary: 0.001kV~65kV (settable)<br />
PT secondary: 1~398V (settable)</div>
</td>
</tr>
<tr>
<td>
<div>Current</div>
</td>
<td>
<div>0.2%</div>
</td>
<td>
<div>0.001A</div>
</td>
<td>
<div>CT primary: 1~9,999A (settable)<br />
CT secondary: 1 A or 5A</div>
</td>
</tr>
<tr>
<td rowspan="2">
<div>Power</div>
</td>
<td rowspan="2">
<div>0.5%</div>
</td>
<td rowspan="2">
<div>0.1W/var/ VA</div>
</td>
<td>
<div> each phase: 0~649.9MW/ Mvar/ MVA</div>
</td>
</tr>
<tr>
<td>
<div>Total: 0~1949.8MW/ Mvar/ MVA</div>
</td>
</tr>
<tr>
<td>
<div>Power Factor</div>
</td>
<td>
<div>0.5%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>-1.000~+1.000</div>
</td>
</tr>
<tr>
<td>
<div>Frequency</div>
</td>
<td>
<div>0.01</div>
</td>
<td>
<div>0.01Hz</div>
</td>
<td>
<div>45~ 65 Hz</div>
</td>
</tr>
<tr>
<td>
<div>Active Energy</div>
</td>
<td>
<div>0.5%</div>
</td>
<td>
<div>0.1kWh</div>
</td>
<td>
<div>0~ 99,999,999.9 kWh</div>
</td>
</tr>
<tr>
<td>
<div>Reactive Energy</div>
</td>
<td>
<div>2.0%</div>
</td>
<td>
<div>0.1kvarh</div>
</td>
<td>
<div>0~ 99,999,999.9 kvarh</div>
</td>
</tr>
<tr>
<td>
<div>Apparent Energy</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.1kVAh</div>
</td>
<td>
<div>0~ 99,999,999.9 kVAh</div>
</td>
</tr>
<tr>
<td>
<div>THD</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
<tr>
<td>
<div>Individual Harmonic</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
<tr>
<td>
<div>Un-balance</div>
</td>
<td>
<div>1.0%</div>
</td>
<td>
<div>0.001</div>
</td>
<td>
<div>0~100.0%</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="r9shd">
<table class="aliDataTable">
<tbody>
<tr>
<td>
<div>Connection mode</div>
</td>
<td>
<div>3-phase 3-wire, 3-phase 4-wire, 1-phase 2-wire</div>
</td>
<td rowspan="5">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<p>Communicati-on</p>
</div>
</td>
<td rowspan="2">
<div>
<div></div>
<div></div>
<p>Modbus-RTU Protocol</p></div>
</td>
<td rowspan="2">
<div>RS485 serial<br />
Baud rate: 2400, 4800, 9600, 19200, 38400bps<br />
Address: 1~247</div>
</td>
</tr>
<tr>
<td>
<div>Metering</div>
</td>
<td>
<div>True RMS, 1 sec refresh time</div>
</td>
</tr>
<tr>
<td>
<div>
<p>Input</p></div>
</td>
<td>
<div>Rate current: 1A or 5A<br />
Rate voltage:<br />
Direct 120, 220V, 240V, 277V, 398Vph-N (optional)<br />
PT secondary: 1~398V (settable)<br />
Frequency: 50/ 60Hz</div>
</td>
<td>
<div>Modbus-TCP/ IP</p>
</div>
</td>
<td>
<div>Ethernet communication port<br />
Support connect 10M/100M ethernet, Modbus TCP/IP, Web, FTP</div>
</td>
</tr>
<tr>
<td>
<div>
<div></div>
<div></div>
<p>Overload</p></div>
</td>
<td>
<div>120% of rated, continuously<br />
Instantaneous current: 10 times/ sec<br />
Instantaneous voltage: 2 times/ sec</div>
</td>
<td rowspan="2">
<div>
<div>BACnet MS/TP protocol</div>
</div>
</td>
<td rowspan="2">
<div>RS485 serial</p>
<div>Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 76800bps</p>
<p>Address: 1&#8230;127, excluding 99</p></div>
</div>
</td>
</tr>
<tr>
<td>
<div>Status input</div>
</td>
<td>
<div>Wet contact, external power supply</div>
</td>
</tr>
<tr>
<td>
<div>Relay output</div>
</td>
<td>
<div>Node capacity: 250VAC/5A</div>
</td>
<td rowspan="3">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Dimension</p>
<p>(L x W x H)</p>
</div>
</div>
</td>
<td colspan="2" rowspan="3">
<div>F-MPM110:</p>
<p>Panel: 96 x 96 x 13.5 mm</p>
<p>Cut-out: 90 x 90 x 58.6 mm (basic)</p>
<p>90 x 90 x 80.1 mm (optional module)</p>
<p>F-MPM110-DR:</p>
<p>Panel: 96 x 96 x 12 mm</p>
<p>Cut-out: 90 x 90 x 58.6 mm (basic)</p>
</div>
</td>
</tr>
<tr>
<td>
<div>Pulse output</div>
</td>
<td>
<div>Pulse constant: 1000~9999 programmable<br />
Pulse width: 60~100ms programmable<br />
Formula: 1 pulse = (1÷ pulse constant ×PT ×CT) kWh</div>
</td>
</tr>
<tr>
<td>
<div>
<div></div>
<p>Power supply</p></div>
</td>
<td>
<div>85 ~265VAC,85~265VDC (When select P1)<br />
100~420VAC, 100~400VDC (When select P2)</div>
</td>
</tr>
<tr>
<td>
<div>Power loss</div>
</td>
<td>
<div>&lt;5VA</div>
</td>
<td>
<div>Weight</div>
</td>
<td colspan="2">
<div>Basic unit: approx 550gr.<br />
Optional module: 50gr.</div>
</td>
</tr>
<tr>
<td>
<div>IP index</div>
</td>
<td>
<div>IP52 (front panel) and IP30 (case)</div>
</td>
<td rowspan="4">
<div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div></div>
<div>Environment</p>
</div>
</div>
</td>
<td rowspan="2">
<div>Main Module &amp; and other Modules</div>
</td>
<td rowspan="2">
<div>Operating temperature: -10℃~ +55 ℃<br />
Storage temperature: -40℃~ +70 ℃<br />
Humidity: 5%~95% non-condensing</div>
</td>
</tr>
<tr>
<td>
<div>Power frequency withstand voltage</div>
</td>
<td>
<div>AC 2KV/minute</div>
</td>
</tr>
<tr>
<td>
<div>Insulation resistance</div>
</td>
<td>
<div>≥50MΩ</div>
</td>
<td rowspan="2">
<div>BACnet Module</div>
</td>
<td rowspan="2">
<div>Operating temperature: 0℃~ +50 ℃</p>
<p>Storage temperature: -5℃~ +75 ℃</p>
<p>Humidity: 10%~95% non-condensing</p></div>
</td>
</tr>
<tr>
<td>
<div>Impulse withstand voltage</div>
</td>
<td>
<div>4kV (peak), 1.2/50uS</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div>
<div id="1v3tv">
<table class="aliDataTable">
<tbody>
<tr>
<td colspan="4">
<div>
<div><b>Standard(EMC)</b></div>
</div>
</td>
</tr>
<tr>
<td>
<div>Electrostatic discharge immunity test</div>
</td>
<td>
<div>IEC 61000-4-2,Level 4</div>
</td>
<td>
<div>Surge immunity test (1, 2/50μs~8/20μs)</div>
</td>
<td>
<div>IEC 61000-4-5,Level 3</div>
</td>
</tr>
<tr>
<td>
<div>Radiated immunity test</div>
</td>
<td>
<div>IEC 61000-4-3,Level 3</div>
</td>
<td>
<div>Conducted emissions</div>
</td>
<td>
<div>EN 55022,Class B</div>
</td>
</tr>
<tr>
<td>
<div>Electrical fast transient /burst immunity test</div>
</td>
<td>
<div>IEC 61000-4-4,Level 4</div>
</td>
<td>
<div>Radiated emissions</div>
</td>
<td>
<div>EN 55022,Class B</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div>
<div id="xbmo5">
<div id="ali-anchor-AliMaya-tbi65" data-section="AliMaya-tbi65" data-section-title="Installation">Installation</div>
</div>
<div>
<div id="cy9pn">
<div><img fetchpriority="high" decoding="async" src="https://sc02.alicdn.com/kf/HTB11LwNX2jsK1Rjy1Xaq6zispXaS/231921809/HTB11LwNX2jsK1Rjy1Xaq6zispXaS.jpg" width="750" height="174" data-src="//sc02.alicdn.com/kf/HTB11LwNX2jsK1Rjy1Xaq6zispXaS/231921809/HTB11LwNX2jsK1Rjy1Xaq6zispXaS.jpg" /></div>
</div>
</div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/f-mpm110-multifunction-electric-power-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1070</post-id>	</item>
		<item>
		<title>ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase</title>
		<link>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/</link>
					<comments>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Wed, 03 Mar 2021 23:43:47 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=1060</guid>

					<description><![CDATA[ETCR4700 Three Phase Digital Phase Meter 0.0mA~400.0A 0.00V~600V 3 Phase Meter Product Description 1. Intelligent design, reduce the complexity of operation, reduce the possibility of misoperation, with high precision, high stability, low power consumption, easy to use and other advantages. 2. The meter adopts large caliber current clamp, suitable for thick wire and large current testing site, [...]]]></description>
										<content:encoded><![CDATA[<p><strong><span data-spm-anchor-id="a2700.details.0.i36.6bfe57d28lNi1C">ETCR4700 Three Phase Digital Phase Meter 0.0mA~400.0A 0.00V~600V 3 Phase Meter</span></strong></p>
<div id="ali-anchor-AliPostDhMb-c8p9k" data-section="AliPostDhMb-c8p9k" data-section-title="Product Description">
<div id="ali-title-AliPostDhMb-c8p9k">Product Description</div>
<div>
<p data-spm-anchor-id="a2700.details.0.i37.6bfe57d28lNi1C">
<p>1. Intelligent design, reduce the complexity of operation, reduce the possibility of misoperation, with high precision, high stability, low power consumption, easy to use and other advantages.</p>
<p>2. The meter adopts large caliber current clamp, suitable for thick wire and large current testing site, Max current range to 600A.</p>
<p>3. Adopt voltage transformer and current clamp to input, no high voltage inside the meter, complete isolation between 3 input channels, safe and reliable.</p>
<p>4. With USB interface, Data storage: 500 groups. Through the system software to upload the storage data to computer, convenient to read, save, report, print historical data, etc.</p>
<p>&nbsp;</p>
<p><strong>Technical Specification</strong></p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td height="27">Power Supply</td>
<td>   DC9V alkaline batteries(1.5V LR6×6)</td>
</tr>
<tr>
<td height="27">   Clamp</td>
<td>   35mm x 40mm</td>
</tr>
<tr>
<td height="27">   LCD</td>
<td>   240dotsX160dots</td>
</tr>
<tr>
<td rowspan="9" height="241">   Range</td>
<td>   Voltage:AC 0.00V~600V</td>
</tr>
<tr>
<td height="27">   Current:AC 0mA~600A</td>
</tr>
<tr>
<td height="27">   Phase:0.0°~360.0°</td>
</tr>
<tr>
<td height="27">   Frequency:45.00Hz~65.00Hz</td>
</tr>
<tr>
<td height="27">   Active power:0.0W~240kW</td>
</tr>
<tr>
<td height="27">   Reactive power:0.0VAR~240kVAR</td>
</tr>
<tr>
<td height="27">   Apparent Power:0.0VA~240kVA</td>
</tr>
<tr>
<td height="27">   Power factor :-1~+1</td>
</tr>
<tr>
<td height="27">   Current vector:0A~1800A</td>
</tr>
<tr>
<td rowspan="9" height="241">   Resolution</td>
<td>   Voltage:AC 0.01V</td>
</tr>
<tr>
<td height="27">   Current:AC 1mA</td>
</tr>
<tr>
<td height="27">   Phase:0.1°</td>
</tr>
<tr>
<td height="27">   Frequency:0.01Hz</td>
</tr>
<tr>
<td height="27">   Active power:0.1W</td>
</tr>
<tr>
<td height="27">   Reactive power:0.1VAR</td>
</tr>
<tr>
<td height="27">   Apparent Power:0.1VA</td>
</tr>
<tr>
<td height="27">   Power factor:0.001</td>
</tr>
<tr>
<td height="27">   Current vector: 0.1A</td>
</tr>
<tr>
<td height="27">   Accuracy</td>
<td>   ±0.5% range</td>
</tr>
<tr>
<td height="27">   Date Storage</td>
<td>   500 sets</td>
</tr>
<tr>
<td height="27">   Data upload function</td>
<td>   USB interface, the stored data upload computer, easy to analyze management data</td>
</tr>
<tr>
<td height="27">   Auto Power-off</td>
<td>   15 minutes off automatically</td>
</tr>
<tr>
<td rowspan="2" height="54">   Power Consumption</td>
<td>   With backlight: MAX working Current about 80mA, the battery can work continuously for 8 hours</td>
</tr>
<tr>
<td height="27">   without backlight:working current about 50mA,the battery can work continuously for 12 hours</td>
</tr>
<tr>
<td height="27">   Working environment</td>
<td>   -10℃~40℃;below 80%Rh</td>
</tr>
<tr>
<td height="27">   Store environment</td>
<td>   -10℃~60℃; below 70%Rh</td>
</tr>
<tr>
<td rowspan="2" height="54">   Phase sequence</td>
<td>   Positive: U1, U2, U3 or I1, I2, I3 The cursor flashes from left to right</td>
</tr>
<tr>
<td height="27">   Inverting: U1, U2, U3 or I1, I2, I3 The cursor flashes from right to left</td>
</tr>
<tr>
<td rowspan="2" height="54">   The phase range of the measured signal when measuring phase</td>
<td>   Measuring U1-U2 phase: 30V ~ 500V</td>
</tr>
<tr>
<td height="27">   Measuring U1-I2 orI1-U2 Phase:10V~500V,10mA~10.00A</td>
</tr>
<tr>
<td height="27">   Test line length</td>
<td>   1.5m</td>
</tr>
<tr>
<td height="27">   Current clamp length</td>
<td>   2 m</td>
</tr>
<tr>
<td height="27">   measure time</td>
<td>   2s/time</td>
</tr>
<tr>
<td height="27">   Data Hold</td>
<td>   Press the HOLD button during the test to hold the data, the «DH» symbol is displayed</td>
</tr>
<tr>
<td height="27">   input resistance</td>
<td>   Test voltage input impedance is:1MΩ</td>
</tr>
<tr>
<td height="27">   Low battery</td>
<td>   When battery voltage decreases to about 7.2V, battery voltage low icon will display, reminding to replace battery.</td>
</tr>
<tr>
<td height="27">   Withstanding Voltage</td>
<td>   Between the instrument line and the shell to withstand 1000V / 50Hz sine wave AC voltage for 1 minute</td>
</tr>
<tr>
<td height="27">   Insulation</td>
<td>   Between the meter line and the jacket shell ≥ 100MΩ</td>
</tr>
<tr>
<td height="27">   Structure</td>
<td>   Double insulated, with insulated vibration-proof jacket</td>
</tr>
<tr>
<td height="27">   Protection Type</td>
<td>   IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution 2</td>
</tr>
<tr>
<td height="27">   Weight</td>
<td>   1360g</td>
</tr>
<tr>
<td height="27">   Dimension</td>
<td>   196mm×92mm×54mm</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://sc01.alicdn.com/kf/H3e6c12009fa743acb2cd16e4098cf507U/200428247/H3e6c12009fa743acb2cd16e4098cf507U.jpg" alt="ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase Meter" width="750" height="750" data-src="//sc01.alicdn.com/kf/H3e6c12009fa743acb2cd16e4098cf507U/200428247/H3e6c12009fa743acb2cd16e4098cf507U.jpg" data-alt="ETCR4700 Three Phase Digital Phase Meter 0mA~600A 0.00V~600V 3 Phase Meter" /></div>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/etcr4700-three-phase-digital-phase-meter-0ma600a-0-00v600v-3-phase/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1060</post-id>	</item>
		<item>
		<title>3 phases multifunction panel power meter with profibus SD harmonics APM801</title>
		<link>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/</link>
					<comments>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 20:49:48 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=796</guid>

					<description><![CDATA[General APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have ful power measurement, energy Istatistics, analysis of power qualify and network commlyications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network. [...]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="" src="https://sc01.alicdn.com/kf/H1ce637584eee44f3b3ffa673ee230fd50/200461481/H1ce637584eee44f3b3ffa673ee230fd50.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="461" height="49" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-spm-anchor-id="a2700.wholesale.pronpeci14.i0.57d5371cENIxMy" /></p>
<p><strong>General</strong></p>
<table style="height: 5px;" border="1" width="327" data-mce-background-color="#ffffff">
<tbody>
<tr>
<td>APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology.<br />
APM series meters have ful power measurement, energy Istatistics, analysis of power qualify and network commlyications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Appearance</strong></p>
<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/Hbdfd55db27cd40088eb6dfcc192831c6A/200461481/Hbdfd55db27cd40088eb6dfcc192831c6A.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="119" height="119" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="228" data-height="228" /><img loading="lazy" decoding="async" class="" src="https://sc02.alicdn.com/kf/H00f032563f934544a813e55fe144c517j/200461481/H00f032563f934544a813e55fe144c517j.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="168" height="168" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="234" data-height="234" /><img loading="lazy" decoding="async" class="" src="https://sc02.alicdn.com/kf/H9e0e41314367406a863e7025ccd28aa6L/200461481/H9e0e41314367406a863e7025ccd28aa6L.jpg_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="158" height="158" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="230" data-height="230" /></p>
<p>&nbsp;</p>
<p><strong>Product Function</strong></p>
<p><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/Haf48b3207fb842b5bf0da23076c7235eT/200461481/Haf48b3207fb842b5bf0da23076c7235eT.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="361" height="243" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="751" data-height="507" /><img loading="lazy" decoding="async" class="" src="https://sc01.alicdn.com/kf/H41c85d36fb8f43c89d60c46bf8f9de24c/200461481/H41c85d36fb8f43c89d60c46bf8f9de24c.png_.webp" alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" width="557" height="135" data-alt="3 phase multifunction panel power meter with profibus SD harmonics APM801" data-width="752" data-height="182" data-spm-anchor-id="a2700.wholesale.pronpeci14.i1.57d5371cENIxMy" /></p>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/3-phases-multifunction-panel-power-meter-with-profibus-sd-harmonics-apm801/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">796</post-id>	</item>
		<item>
		<title>Analizador multifunciones de armónicos trifásico</title>
		<link>https://tienda.softbi.com.mx/producto/analizador-de-armonicos-trifasico-medidor-de-potencia-analizador-de-calidad-de-energia-electrica-digital-trifasico-electrico/</link>
					<comments>https://tienda.softbi.com.mx/producto/analizador-de-armonicos-trifasico-medidor-de-potencia-analizador-de-calidad-de-energia-electrica-digital-trifasico-electrico/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Fri, 29 Jan 2021 20:28:38 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=790</guid>

					<description><![CDATA[Descripción del producto I. funcionales F sticasoperativas 1. El instrumento se utiliza especialmente para detectar problemas de calidad de la energía, como distorsión de la forma de onda, contenido armónico, fluctuación y parpadeo de voltaje y desequilibrio trifásico en la red eléctrica. También tiene las funciones de prueba de parámetros eléctricos y análisis de vectores. 2. Puede medir con [...]]]></description>
										<content:encoded><![CDATA[<div id="ali-title-AliPostDhMb-hu61a"><span data-spm-anchor-id="a2700.details.pronpeci14.i0.5356eed3m4btOB">Descripción del producto</span></div>
<div>
<p><strong>I. </strong><strong>funcionales </strong><strong>F </strong><strong>sticasoperativas</strong></p>
<p>1. El instrumento se utiliza especialmente para detectar problemas de calidad de la energía, como distorsión de la forma de onda, contenido armónico, fluctuación y parpadeo de voltaje y desequilibrio trifásico en la red eléctrica. También tiene las funciones de prueba de parámetros eléctricos y análisis de vectores.</p>
<p>2. Puede medir con precisión voltaje, corriente, potencia activa, potencia reactiva, ángulo de fase, factor de potencia, frecuencia y otros parámetros eléctricos.</p>
<p>3. Se puede mostrar el diagrama vectorial de voltaje y corriente medidos. Los usuarios pueden obtener el cableado correcto de los equipos de medición analizando el diagrama vectorial.</p>
<p>4. La corriente se mide con un transformador tipo pinza. Debido a que el operador no necesita desconectar el bucle de corriente cuando mide con el transformador de corriente de pinza, la medición se puede realizar de manera conveniente y segura. De acuerdo con el rango de medición diferente del usuario se puede seleccionar con diferentes rangos de mesa de sujeción.</p>
<p>5. Puede medir y analizar la calidad de energía de CA de la red eléctrica pública para el cliente, y su medición y análisis incluyen desviación de frecuencia, desviación de voltaje, fluctuación de voltaje, parpadeo, grado de desequilibrio permitido de voltaje trifásico y armónico de red.</p>
<p>6.  Se pueden mostrar formas de onda de voltaje y corriente monofásicas, y se pueden mostrar formas de onda de voltaje y corriente trifásicas al mismo tiempo.</p>
<p>7.  Todas las interfaces de prueba tienen función de bloqueo de pantalla para facilitar la lectura del usuario y el análisis de datos.</p>
<p>8.  Supervisión de la fluctuación de carga: mide y analiza la fluctuación de la calidad de la energía de la red eléctrica pública causada por varios equipos eléctricos en diferentes estados operativos. Registre y almacene periódicamente la tendencia cambiante de los parámetros de potencia, como voltaje, corriente, potencia activa, potencia reactiva, potencia aparente, frecuencia y fase.</p>
<p>9. Monitoreo dinámico del proceso de ajuste y operación de equipos de energía, ayuda a los usuarios a resolver problemas en el proceso de ajuste y operación de equipos de energía.</p>
<p>10.  Capaz de probar y analizar parámetros dinámicos de compensación de potencia reactiva y dispositivos de filtrado en el sistema de energía y hacer una evaluación cuantitativa de sus funciones e indicadores técnicos</p>
<p>11. Se pueden configurar diferentes intervalos de tiempo de almacenamiento para almacenar datos continuamente en el intervalo establecido;</p>
<p>12. El almacenamiento de datos de gran capacidad incorporado, que se puede almacenar a intervalos de un minuto durante más de 18 meses, puede satisfacer las necesidades de los sitios de prueba de monitoreo a largo plazo.</p>
<p>13. El instrumento tiene una interfaz USB, que puede copiar datos de manera conveniente directamente a la computadora de administración en segundo plano.</p>
<p>14.  Con un potente software de gestión de datos, los datos de muestreo en tiempo real se pueden cargar directamente en la computadora de gestión en segundo plano para un procesamiento más completo y rápido en segundo plano.</p>
<p>15.  Con funciones de calendario y reloj, visualización en tiempo real de fecha y hora. Los datos de prueba y los resultados se pueden guardar al mismo tiempo que las pruebas en el sitio y cargarse en la computadora a través del puerto serie. La microgestión de datos se puede realizar mediante un software de gestión en segundo plano (accesorios opcionales), con una potente función de generación de informes.</p>
<p>16. Adopte cristal líquido de color importado de pantalla grande como pantalla, interfaz de operación en chino y  caracteres en inglés , información rápida, interfaz de pantalla de cristal líquido de pantalla de múltiples parámetros, interfaz de diálogo hombre-máquina amigable.</p>
<p>La pantalla LCD sin funcionamiento de 17. minutos entra automáticamente en el modo de ahorro de energía para maximizar el tiempo de trabajo de la batería.</p>
<p>18. Botón de silicona conductora, buen tacto, larga vida, diseño razonable, fácil de operar.</p>
<p>19. Batería recargable de iones de litio incorporada de gran capacidad y alto rendimiento , que puede funcionar continuamente durante más de 10 horas con carga completa .</p>
<p>20. Tamaño pequeño, peso ligero, fácil de transportar, se puede utilizar para mediciones de campo, también se puede utilizar como equipo de medición estándar del laboratorio.</p>
<p><strong>II. </strong><strong>Técnica </strong><strong>I </strong><strong>NDICADORES</strong></p>
<p>1. Funciones de entrada</p>
<p>Rango de medición de voltaje: 0 ~ 200V ~ 800V, corte automático.</p>
<p>Rango de medición de corriente</p>
<p>Transformador tipo abrazadera (tres tipos): 5A / 25A (estándar)</p>
<p>100A / 500A (opcional)</p>
<p>400A / 2000A (opcional)</p>
<p>Rango de medición del ángulo de fase: 0 ~ 359,99 °.</p>
<p>Rango de medición de frecuencia: 45 ~ 55Hz.</p>
<p>Canales de tensión: tres canales U <sub>A</sub> , U <sub>B</sub> , U <sub>C</sub> ).</p>
<p>Número de canales actuales: tres canales (I <sub>A</sub> , I <sub>B</sub> , I <sub>C</sub> ).</p>
<p>Número máximo de análisis de armónicos: 63  veces</p>
<p>Ciclo máximo de almacenamiento continuo de intervalo de 1 minuto: 18 meses.</p>
<p>2.  Precisión</p>
<p>Medición de parámetros eléctricos:</p>
<p>Voltaje : ± 0,2%</p>
<p>Frecuencia: ± 0.01Hz</p>
<p>Corriente y potencia: ± 0,5%</p>
<p>Fase : ± 0,2 °</p>
<p>Calidad de energía:</p>
<p>Error permisible de voltaje de onda fundamental ≤ 0.5% FS</p>
<p>Error admisible de la corriente fundamental: ≤ 1% FS</p>
<p>Error de medición de la diferencia de fase entre el voltaje de onda fundamental y la corriente: ≤0.2 °</p>
<p>La tensión armónica contiene un error de medición de la tasa: ≤ 0,1%</p>
<p>Corriente armónica que contiene el error de medición de la tasa: ≤ 0,2%</p>
<p>Error de desequilibrio de tensión trifásica: ≤ 0,2%</p>
<p>Error de desviación de voltaje: ≤ 0,2%</p>
<p>Error de variación de voltaje: ≤ 0,2%</p>
<p>1. Temperatura de funcionamiento: -10 ℃ ~ + 40 ℃</p>
<p>2. Fuente de alimentación de carga: AC220V, frecuencia: 45 hz-55 hz</p>
<p>3. Consumo de energía del host: ≤3VA</p>
<p>4. Tiempo máximo de funcionamiento de la batería: ≤10 horas</p>
<p>5. Aislamiento:</p>
<p>1) Resistencia de aislamiento de los terminales de entrada de voltaje y corriente al chasis≤100MΩ</p>
<p>2) la frecuencia de alimentación entre el extremo de entrada de la fuente de alimentación de trabajo y la carcasa es de 1,5 KV  (valor efectivo), y el experimento dura 1 minuto.</p>
<p>6. Dimensión : 320 mm × 240 mm × 130 mm</p>
<p data-spm-anchor-id="a2700.details.pronpeci14.i1.5356eed3m4btOB">7. Peso: 2,0 kg</p>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://tienda.softbi.com.mx/producto/analizador-de-armonicos-trifasico-medidor-de-potencia-analizador-de-calidad-de-energia-electrica-digital-trifasico-electrico/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">790</post-id>	</item>
		<item>
		<title>BJ194J-9SY Analizador multi tarifario monitor de energía para oficina o edificios</title>
		<link>https://tienda.softbi.com.mx/producto/bj194j-9sye-power-analyzer-mqtt-multi-tariff-power-energy-monitor-for-office-building-sub-metering/</link>
					<comments>https://tienda.softbi.com.mx/producto/bj194j-9sye-power-analyzer-mqtt-multi-tariff-power-energy-monitor-for-office-building-sub-metering/#respond</comments>
		
		<dc:creator><![CDATA[001RoBerto]]></dc:creator>
		<pubDate>Thu, 28 Jan 2021 19:43:13 +0000</pubDate>
				<guid isPermaLink="false">https://tienda.softbi.com.mx/?post_type=product&#038;p=742</guid>

					<description><![CDATA[Product Description New 194J series Smart Power Manager is the more powerful meter than 194Y series power analyzer. With higher precision and more measurement parameters. This meter is the latest series meter developed in 2015 by Blue Jay tech. It is the ideal choice for monitoring and controlling of power distribution systems. &#160; Application: &#160; [...]]]></description>
										<content:encoded><![CDATA[<div>
<div id="bkxi4">
<div id="ali-anchor-AliMaya-3234d" data-section="AliMaya-3234d" data-section-title="Product Description">Product Description</div>
</div>
<div>
<div id="xoo0n">
<p>New 194J series Smart Power Manager is the more powerful meter than 194Y series power analyzer. With higher precision and more measurement parameters.</p>
<p>This meter is the latest series meter developed in 2015 by Blue Jay tech. It is the ideal choice for monitoring and controlling of power distribution systems.</p>
<p>&nbsp;</p>
<p>Application:</p>
<p>&nbsp;</p>
<p>·Metering of distribution feeders, transformers, generators, capacitor banks and motors.<br />
·Medium and low voltage systems.<br />
·Harmonic analyze.<br />
·Remote data reading.</p>
</div>
</div>
</div>
<div>
<div id="vsz3s">
<div id="ali-anchor-AliMaya-k936y" data-section="AliMaya-k936y" data-section-title="Detailed Images">Detailed Images</div>
</div>
<div>
<div id="x12ha">
<div><img loading="lazy" decoding="async" src="https://sc02.alicdn.com/kf/HTB1E9K0JhSYBuNjSsphq6zGvVXao/205970117/HTB1E9K0JhSYBuNjSsphq6zGvVXao.jpg_.webp" width="371" height="278" /></div>
</div>
<div>
<div id="o23pf">
<h3>Features</h3>
</div>
<div id="6zlng">
<p data-spm-anchor-id="a2700.details.pronpeci14.i0.29e778bbrV8afi">·Class 0.2 power and energy<br />
·Current measuring &#8230;/5 or &#8230;/1 A<br />
·Backlit LCD display<br />
·Expandable input / output modules (up to 3 modules)<br />
·With RS-485 Modbus/RTU Communications<br />
·Measured varies of power parameter. (Max demand/unbanlance/crest factor/K factor&#8230;)<br />
·Optional 2 channel Digital Input (DI) and 3 channel Digital Output (DO)<br />
·Record and read multi- tariffs ratio, Up to 3 months<br />
·Provide max 50 lists SOE record function<br />
·ITF Technology: galvanic insulation protection inputs outputs<br />
·Universal series power supply (85-265VAC/DC)</p>
</div>
</div>
</div>
</div>